background image

Wattstopper

 

®

Low Voltage, Continuous Dimming, PIR Fixture Integrated Outdoor Sensor 

In IP66 Enclosure with Bluetooth low energy technology
Basse Tension, Gradation Continue, Luminaire avec détecteur IRP 

extérieur intégré dans un boitier IP66 avec Bluetooth basse consommation
Sensor PIR de bajo voltaje para luminarias de exterior, tipo IP66 con 

función de Atenuación Continua y con Bluetooth de bajo consumo

Installation Instructions • Instructions d’Installation • Instrucciones de Instalación

No: 25745 –  03/20  rev. 9

Catalog Numbers • Les Numéros de Catalogue • Números de Catálogo: FSP-301B, FSP-301B-S, FSP-301B-D

Country of Origin: Made in China • Pays d’origine: Fabriqué en Chine • País de origen: Hecho en China

DESCRIPTION AND OPERATION

The FSP-301B is an IP66 rated motion sensor that dims lighting from high to 

low based on movement. 
Three configurations are available. The FSP-301B mounts inside the fixture 

and the PIR lens connects to the FSP-301B through a 1.30” diameter hole 

in the bottom of the fixture. The FSP-301B-S mounts to a fixture/enclosure 

with a 1/2” knock out, via a nipple on the back. The FSP-301B-D has a drop 

mount nipple, for mounting on to a pole, or to a fixture.
The sensor uses passive infrared (PIR) sensing technology that reacts to 

changes in infrared energy (moving body heat) within the coverage area. Once 

the sensor stops detecting movement and the time delay elapses, lights will go 

from high to low mode and eventually to an OFF position if it is desired. Sensors 

must directly “see” motion of a person or moving object to detect them, so careful 

consideration must be given to sensor luminaire placement and lens selection. 

Avoid placing the sensor where obstructions may block the sensor’s line of sight.
The FSP-301B has a photocell that can read the light level and continuously 

raise or lower the dimming level of the lighting loads, based on the ambient light and desired light level setting.
The FSP-301B operates at 12–32 VDC. It is designed to be installed in indoor and outdoor environments.

NOTE: 

When the FSP-301B is powered up the first time, it will use factory default parameters to operate. If adjustments are needed, 

the Sensor Configuration mobile app must be used.

This device complies with Industry Canada licence-exempt RSS standard(s). 

Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, 

including interference that may cause undesired operation of the device. 

Light

Sensor

Motion Indicator

Blue LED

PIR Sensor

Reset Button

Sensor Protection Cap

NOTE: Remove Cap before use

Voltage  ...............................................................12–32 VDC 
Current Consumption ................................. 15 mA maximum
Wiring .......................................................................22 AWG
 Length 

 .......... 36” (91.44cm), 30” (76.2cm) from nipple

 

Primary Voltage .................................. +VDC, Com, Ctrl

 

Control Output .................................. 100 mA maximum

 

Dimming Voltage .................Dim + (violet), Dim - (gray)

Operating Temperature ..........-40°F (-40°C) to 167°F (75°C)
Tightening Skirt/Nut Torque ................................ 25-30 in-lbs
Dimensions
 Collar ......................................1.30” diameter (33.0mm)
 

Collar height ..........................................0.64” (16.3mm)

 Body .... 5.7”L x 2.3”W x 3.5”H (145mm x 60mm x 90mm)
Weight ...............................................................2.8 oz (80 g)
Enclosure .................................................IP66 (NEMA STD)
Coverage
 

FSP-L2 Lens @ 8’ height ................. up to 44’ diameter

 

FSP-L3 Lens @ 20’ height ............... up to 40’ diameter

 

FSP-L7 Lens @ 40’ height ............. up to 100’ diameter

Adjustments and Features
 

High Mode .................................................0 V – 10 V

 

Low Mode  ...................................0 V – 9 V, Disabled

 

Time Delay .................... 30 seconds, 1 min – 30 min

 

Cut Off ............... Disable, 1 min – 59 min ,1 hr – 5 hr

 Sensitivity ................ On-Fix, Off-Fix, Low, Med, High
 

Hold Off Setpoint ................ Auto, Disabled, 1–250 fc

 

Ramp Up ............................ Disabled, 1 sec – 60 sec

 

Fade Down ......................... Disabled, 1 sec – 60 sec

 

Photocell Setpoint for On/Off .......Disabled, 1–250 fc

 

Continuous Dimming ....................Disabled, 0–250 fc

Factory Defaults
 

High Mode .......................................................... 10 V

 

Low Mode  ............................................................ 1 V

 

Time Delay ........................................................5 min

 

Cut Off ................................................................. 1 hr

 Sensitivity 

 .......................................................... High

 

Hold Off Setpoint  .........................................Disabled

 

Ramp Up ......................................................Disabled

 

Fade Down ...................................................Disabled

 

Photocell Setpoint for On/Off .......................Disabled

 

Continuous Dimming ....................................Disabled 

SPECIFICATIONS

Содержание Wattstopper FSP-301B

Страница 1: ...usly raise or lower the dimming level of the lighting loads based on the ambient light and desired light level setting The FSP 301B operates at 12 32 VDC It is designed to be installed in indoor and o...

Страница 2: ...face of the fixture If needed add the nut between the sensor body and the rubber gasket to ensure a secure fit Install the nipple nut securely against the fixture to a torque of 25 30 in lbs to ensure...

Страница 3: ...TE Bluetooth communication ranges can vary depending on the device as well as mobile carrier Wattstopper recommends devices with Bluetooth 5 0 Iphone 8 and Samsung Galaxy S8 and later devices are reco...

Страница 4: ...setpoint needs to be adjusted If set for minimum more than 1 fc at the sensor of ambient light will cause the lights to be held OFF See the new settings section for instructions If lights still do not...

Страница 5: ...digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment...

Страница 6: ...e fixation suspendu pour l installation sur un poteau ou sur un luminaire Le d tecteur utilise la technologie de d tection par infrarouge passif IRP qui r agit aux changements dans l nergie infrarouge...

Страница 7: ...en caoutchouc au raccord et installez le d tecteur face vers le bas Assurez vous que le joint en caoutchouc touche la surface du luminaire Si n cessaire ajoutez l crou entre le corps du d tecteur et...

Страница 8: ...ppareils iOS et Android Rechercher Wattstopper Sensor Config sur votre appareil pour le t l charger REMARQUE La qualit du signal et la distance de communication Bluetooth peuvent varier en fonction de...

Страница 9: ...haut V rifiez toutes les connexions et la charge et assurez vous que les fils de terre sont bien fix s Assurez vous que le d tecteur n est pas obstru V rifiez le param tre du niveau de luminosit pour...

Страница 10: ...ous tension il se produit un pr chauffage de 50 secondes La charge s teindra apr s le temps de pr chauffage si aucun mouvement n est d tect RENSEIGNEMENTS POUR COMMANDES Num ro de Catalogue Descriptio...

Страница 11: ...tilisateur doivent tre maintenu en tout temps Tout changement ou modification non express ment approuv par The Watt Stopper Inc pourrait annuler le droit de l utilisateur utiliser l quipement D CLARAT...

Страница 12: ...boquilla detr s El FSP 301B D posee una boquilla de montaje de ca da para montar en un polo o en la luminaria Los sensores usan tecnolog a de detecci n de infrarrojo pasivo PIR que reacciona a los ca...

Страница 13: ...de 22 mm 0 875 de di metro a trav s del polo 3 Agregue la empaque de goma a la boquilla e instale el sensor boca abajo Aseg rese de que la empaque de goma toque la superficie de la luminaria Si es ne...

Страница 14: ...el sensor est disponible para dispositivos iOS y Android Busque Wattstopper Sensor Config en su dispositivo para descargar NOTA Los rangos de comunicaci n Bluetooth pueden variar seg n el dispositivo...

Страница 15: ...s luces no pasan al Modo alto Controle todas las conexiones de cables y verifique la carga y que los cables de regulaci n est n bien ajustados Aseg rese de que el sensor no est bloqueado Controle el p...

Страница 16: ...entamiento La carga se apagar despu s del tiempo de calentamiento si no se detecta movimiento INFORMACI N PARA HACER PEDIDOS N de cat logo Descripci n FSP 301B Fase simple doble universal Atenuaci n C...

Страница 17: ...osici n a radiofrecuencia RF la FCC e IC para dispositivos m viles Este dispositivo solo est autorizado para su uso en una aplicaci n m vil Al menos 20 cm de distancia de separaci n entre este disposi...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...on ou la performance de ce produit ou tout autre dommage indirect li la perte de propri t de revenus ou de profits ou aux co ts d enl vement d installation ou de r installation WattStopper garantiza q...

Отзывы: