Tynetec, a business unit of Legrand Electric Ltd
Cowley Road, Blyth Riverside Business Park, Blyth, Northumberland, NE24 5TF.
Tel: +44 (0) 1670 352371 www.tynetec.co.uk
Trusted Technology
Caring for People
869MHz
Flood Detector
_________________________________________________________________________
________________________________________________________________
Doc No. FM0846 V1.02 Page 1
•
Fixed trigger device
•
Compatible with Reach IP, XT2, Carer Response & NOVO
•
Moisture bridge sensor
•
Free standing or screw fixed
•
5 year Lithium battery (typical)
•
Low battery warning
•
Operating Temperature: +5
o
C to +40
o
C
•
Telecare Transceiver: 869.2125MHz Class 1.5
•
Digital Heartbeat
•
Weight: 36 grams
•
Dimensions: 50 x 95 x 18mm (HxWxD)
•
Product Code: ZXT815 (or Neat: NE1020006-02)
Flooding caused by taps left running unattended, a
blocked toilet or a leaking pipe can mean costly repair bills
and potentially create dangerous conditions that could
result in a slip or a fall or damp related health conditions.
Once installed in the bathroom or kitchen, the flood
detector will provide an early warning of a possible flood
situation before it causes extensive damage to carpets,
décor and electrical equipment.
Positioning
The flood detector can be placed on the floor below the
wash basin or kitchen sink, or in the bathroom near the
toilet or alongside the bath. It can be left free-standing or
fixed to the skirting board with the screw or self-adhesive
pad provided.
Alarm Condition
An alarm will be raised when water on the floor bridges
the two contacts on the underside of the flood detector.
IMPORTANT:
following an alarm the flood detector should
be removed from the affected area until the carpet or
flooring is thoroughly dried.
Low Battery Condition
A low battery condition will be reported automatically to
the Alarm Receiving Centre (ARC) or the local Manager.
Once a low battery call is received the flood detector
should be replaced within 30 days. Flood detectors can be
returned to Tynetec for battery replacement.
Out of Range Notification (Reach IP/NOVO)
The Reach IP/NOVO can monitor all radio peripheral
devices to determine whether they have been damaged or
removed from an installation.
Should the Reach IP/NOVO
be unable to detect a device’s
heartbeat it will automatically generate a “radio out of
range” notification. Fi
rstly,
investigate if there’s a genuine
reason for the alert, if not, arrange for the peripheral
device to be replaced immediately.
The “Radio
out of range t
imer” can be set from 30 hours to
99999 hours in CMP. “Radio
s
upervision” can be disabled
by unchecking the tick box associated with each peripheral
device in CMP.
Maintenance
The flood detector can be cleaned with a damp cloth or an
anti-bacterial wipe, do not use solvents or cleaners.
Do not immerse in water.
Disposal
Waste electrical products should not be disposed
of with normal household waste. The flood
detector is ideally suited for disposal within the
waste electronic and electrical equipment
(WEEE) recycling scheme. Please recycle where facilities
exist. Check with your local authority or contact your
supplier for recycling/disposal advice.