Carbon Monoxide Alarm 
869MHz

 

Caring for People 

 
 

 

 
_________________________________________________________________________

 

________________________________________________________________ 

 
 

 
 

 

 

  Doc No. FM0824 V1.01 Page 2   

 

The unit will sound an 
audible alarm consisting of 
2 cycles of 4 loud beeps, 
then stop automatically. 
The red light on the alarm 
will flash rapidly during the 
audible signal. 

The Radio ID is a 10-digit 
code printed on the radio 
module label on the back of 
the CO alarm

  

When activated the 
green power light will 
flash once every 60 
seconds.  

 

Retain the disabling 
clip for future use.

 

To mount on a wall or 
ceiling; push-out the 
screw hole blanking 
plugs in the rear with a 
screwdriver and mark 
the position for the drill 
holes.  Please ensure 
that you use the screws 
and wall plugs provided 
as they were chosen 
specifically for use with 
this product.

 

ZXT812

 

S:081923628  
Iss-1 

17930833F6

   

19W8

 

How to activate the CO Alarm

 

To activate the alarm, remove the metal disabling clip by 
pulling it out of the back of the alarm.  

 

 

 

 

 
How to install the CO Alarm 

Make sure you have read and understood the instructions 
on positioning the alarm before starting. 
 
 

 

 

 

 

 

 
Alternatively, the unit can be fixed with the self-adhesive 
pads provided. Ensure the surface is smooth, clean and 
dry. Press hard to make sure the self-adhesive pads are 
properly adhered.

 

It can also be positioned free-standing 

on a shelf.

 

 

How to test the CO Alarm

  

Press the Test/

 button in the centre and release.  

 

 
 
 
 

 

Telecare Radio ID

 

The CO alarm includes a plug-in radio transceiver module 
to communicate with the Reach IP or XT2. 

 

 

Registering the CO Alarm onto a Reach IP

 

Login to Pulse CMP (www.tynetecpulse.com) and enter 
the Reach IP Serial No. in the 

ALARM UNIT

 view. Press the 

Accessories

 button and enter the Radio ID code, Location 

and Equipment type. Press 

Save

 then 

 

Synchronize

.

 

 

Alternatively, with the Reach IP in normal operating mode 
undo the fixing screw and remove the stand or connector 
cover to access the 

 Power button.

 

 

 

Press the 

 Power button to enter Control Mode, then 

press and hold the 

 button until the unit announces 

add radio device

” then release. 

 

Press the 

 button to confirm then activate the alarm by 

pressing the Test button.  
The 

Reach IP unit will sound a high beep if it’s a new 

device and announce “

range test mode

.  

Press 

 to confirm, or press 

 to step to the next 

function, or press 

 to exit the mode. 

 

 

Registering the CO Alarm onto an Advent XT2

 

Radio Device Programming can only be performed from 

the Advent XT2 Manager’s Panel designated as the 

Controller

. Login using the Manager or Engineer password 

and touch the Programming button.  
Select the 

Program Radio Devices

 option from the 

Program Setting drop-down list.

 

 

 
 
 
 
 
 
 
 
 
 

Enter the 

Radio ID: 

this is the 10-digit code taken from the 

radio module label on the back of the alarm. 
Enter the 

Flat ID: 

this is the flat number the alarm is being 

installed in. Enter 4-digits e.g. 0014. 
Enter the 

Location: 

select where the alarm is

 

located from 

the drop-down list e.g. Living Room. 
Press the 

Send

 button to update the XT2 system. 

 Power Button 