The unit will sound an
audible alarm consisting of
2 cycles of 4 loud beeps,
then stop automatically.
The red light on the alarm
will flash rapidly during the
audible signal.
The Radio ID is a 10-digit
code printed on the radio
module label on the back of
the CO alarm
…
When activated the
green power light will
flash once every 60
seconds.
Retain the disabling
clip for future use.
To mount on a wall or
ceiling; push-out the
screw hole blanking
plugs in the rear with a
screwdriver and mark
the position for the drill
holes. Please ensure
that you use the screws
and wall plugs provided
as they were chosen
specifically for use with
this product.
ZXT812
S:081923628
Iss-1
17930833F6
19W8
How to activate the CO Alarm
To activate the alarm, remove the metal disabling clip by
pulling it out of the back of the alarm.
How to install the CO Alarm
Make sure you have read and understood the instructions
on positioning the alarm before starting.
Alternatively, the unit can be fixed with the self-adhesive
pads provided. Ensure the surface is smooth, clean and
dry. Press hard to make sure the self-adhesive pads are
properly adhered.
It can also be positioned free-standing
on a shelf.
How to test the CO Alarm
Press the Test/
button in the centre and release.
Telecare Radio ID
The CO alarm includes a plug-in radio transceiver module
to communicate with the Reach IP or XT2.
Registering the CO Alarm onto a Reach IP
Login to Pulse CMP (www.tynetecpulse.com) and enter
the Reach IP Serial No. in the
ALARM UNIT
view. Press the
Accessories
button and enter the Radio ID code, Location
and Equipment type. Press
Save
then
Synchronize
.
Alternatively, with the Reach IP in normal operating mode
undo the fixing screw and remove the stand or connector
cover to access the
⚫
Power button.
Press the
⚫
Power button to enter Control Mode, then
press and hold the
button until the unit announces
“
add radio device
” then release.
Press the
⚫
button to confirm then activate the alarm by
pressing the Test button.
The
Reach IP unit will sound a high beep if it’s a new
device and announce “
range test mode
”
.
Press
⚫
to confirm, or press
to step to the next
function, or press
to exit the mode.
Registering the CO Alarm onto an Advent XT2
Radio Device Programming can only be performed from
the Advent XT2 Manager’s Panel designated as the
Controller
. Login using the Manager or Engineer password
and touch the Programming button.
Select the
Program Radio Devices
option from the
Program Setting drop-down list.
Enter the
Radio ID:
this is the 10-digit code taken from the
radio module label on the back of the alarm.
Enter the
Flat ID:
this is the flat number the alarm is being
installed in. Enter 4-digits e.g. 0014.
Enter the
Location:
select where the alarm is
located from
the drop-down list e.g. Living Room.
Press the
Send
button to update the XT2 system.
⚫
Power Button