Doc No. FM0458 issue F Page 4
Registering a Flood Detector onto an
Altec Response
local carer alarm unit
1.
Put the Altec Response unit into radio device learn mode…
2. Activate the flood detector
…
3. Exit the Alt
ec Response radio device learn mode…
4. Activate the flood detector and check a flood alarm is displayed on the Altec Response unit.
Deleting a Flood Detector from an
Altec Response
local carer alarm unit
Press
ENTER
to activate the wake-up display then
ENTER
again to display the main menu
Press
ENTER
to select
Radio Devices
Press the
key
to select
Delete Device
then press
ENTER
The display
will prompt you to “
Trigger the Sensor
”
Activate the flood detector to be deleted - the display will show the device type and its 8 digit ID number
If this is the device you activated press the
key to select
Delete
then press
ENTER
If it’s NOT the device you activated press the
ENTER
key to select
Reject
then try again
To exit the mode select
Exit
then press the
ENTER
key.
Refer to the Altec Response installation guide (Doc No. FM0548) provided with the portable alarm unit for
more information on programming and testing radio devices.
Place a damp cloth across the 2 brass studs on the bottom of the flood detector.
The display will show
Flood
and the flood detector 8 digit ID number.
Check the ID is correct, press the
key to select
Accept
then press
ENTER
.
Note: if another device has been picked-up press
ENTER
to
Reject
and try again
.
The display will show
Flat
, use the
&
keys to choose the dwelling type.
Press the
key
to select
No: 000000
then press the
ENTER
key.
Use the
&
keys to select each digit of the flat number and the
&
keys
to move between digits then press the
ENTER
key.
Press
key
several times to select
Exit
then press the
ENTER
key.
The display
will prompt you to “
Trigger the Sensor
”
again.
Press
ENTER
to activate the wake-up display then
ENTER
again to display
the main menu.
Press
ENTER
to select
Radio Devices
Press
ENTER
to select
Learn Device
The display
will prompt you to “
Trigger the Sensor
”.
You now have 20 seconds to activate the flood detector.
From the
Learn Device
menu select
Exit
then press
ENTER
.
From the
Radio Devices
menu select
Exit
then press
ENTER
.
The display will return to the wake-up screen and go blank after 10 seconds.
The Altec Response is now back in normal operating mode.
tynetec