background image

5 / 5 

 

Thermal relays RTX

Thermal relays RTX

Thermal relays RTX

Thermal relays RTX    

 

Cat N°(s)

Cat N°(s)

Cat N°(s)

Cat N°(s)    : : : : 0 

0 294 58/59/60/61/62/63/64/65/66/67/68/69/70/71/72/ 

294 58/59/60/61/62/63/64/65/66/67/68/69/70/71/72/ 

294 58/59/60/61/62/63/64/65/66/67/68/69/70/71/72/ 

294 58/59/60/61/62/63/64/65/66/67/68/69/70/71/72/ 

73/74/75/76/77/78/82/83/84/85/86/87/88                                             

73/74/75/76/77/78/82/83/84/85/86/87/88                                             

73/74/75/76/77/78/82/83/84/85/86/87/88                                             

73/74/75/76/77/78/82/83/84/85/86/87/88                                             

0 294 94/95

294 94/95

294 94/95

294 94/95

    

 

 

8.4. Operation in automatic reset with stop

8.4. Operation in automatic reset with stop

8.4. Operation in automatic reset with stop

8.4. Operation in automatic reset with stop    

The thermal relay is automatically reset after the cooling of bi-metal. 

A pushing on the test button is used to stop the load. 

 

    

8.5. 

8.5. 

8.5. 

8.5. Operation in automatic reset with

Operation in automatic reset with

Operation in automatic reset with

Operation in automatic reset without

out

out

out    stop

stop

stop

stop    

The thermal relay is automatically reset after the cooling of bi-metal.

 

    

 

 

 

 
 

 

 

 

 

 
 

 

 
 

 

 
 

 

 
 

 

 
 

 

 
 

 

 
 

 

 
 

 

 
 

 

 
 

 

 
 

 

 
 

 

 

  Technical data sheet: F01169EN/00 

Updated on: / 

Created on: 13/12/2012 

 

 

 

Содержание RTX Series

Страница 1: ...9A up to 40A 2 5A 4A 0 294 63 For CTX 1 from 9A up to 40A 4A 6 3A 0 294 64 For CTX 1 from 9A up to 40A 5 5A 8 5A 0 294 65 For CTX 1 from 9A up to 40A 8A 12A 0 294 66 For CTX 1 from 9A up to 40A 10A 16A 0 294 67 For CTX 1 from 9A up to 40A 14 5A 18A 0 294 68 For CTX 1 from 9A up to 40A 17 5A 22A 0 294 69 For CTX 1 from 9A up to 40A 21A 26A 0 294 70 For CTX 1 from 9A up to 40A 25A 32A 0 294 71 For C...

Страница 2: ... up to 0 294 88 Class 10A 10 10 10 Setting range A 0 65 40 24 110 63 190 120 310 Suitable for CTX 1 9A up to 40A CTX 1 50A up to 105A CTX 2 150A up to 185A CTX 2 250A up to 310A Power circuit Rated insulation voltage Ui IEC947 4 V 690 1000 1000 1000 Frequency limits Hz 0 400 0 400 0 400 50 60 Wiring capacity Clamp terminal rigid conductor mm2 6 50 120 Clamp terminal flexible conductor mm2 4 35 120...

Страница 3: ...7 TRIPPING CURVES RTX 1 reference 0 294 58 up to 0 294 71 class 10A RTX 1 reference 0 294 72 up to 0 294 78 class 10 RTX 2 reference 0 294 82 up to 0 294 85 class 10 RTX 2 reference 0 294 86 up to 0 294 88 class 10 Technical data sheet F01169EN 00 Updated on Created on 13 12 2012 Multiple of setting current One phase Cold condition Three phases Cold condition Three phases Heat condition Tripping t...

Страница 4: ...TEST TEST TEST TEST Fonction Fonction Fonction Fonction When the test button is pressed the status of auxiliary contacts change 8 2 8 2 8 2 8 2 Operation in manual reset Operation in manual reset Operation in manual reset Operation in manual reset The thermal relay must be reset by pressing the test button in order to restart the load 8 3 8 3 8 3 8 3 Operation in manual reset and stop Operation in...

Страница 5: ...88 0 0 0 0 294 94 95 294 94 95 294 94 95 294 94 95 8 4 Operation in automatic reset with stop 8 4 Operation in automatic reset with stop 8 4 Operation in automatic reset with stop 8 4 Operation in automatic reset with stop The thermal relay is automatically reset after the cooling of bi metal A pushing on the test button is used to stop the load 8 5 8 5 8 5 8 5 Operation in automatic reset with Op...

Отзывы: