![LEGRAND Pass & Seymour LightSense PSHCF Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/legrand/pass-and-seymour-lightsense-pshcf/pass-and-seymour-lightsense-pshcf_installation-instruction_1870916005.webp)
Visit our website for FAQs: www.passandseymour.com
OPERATION
Before use, set the fan to run in the appropriate direction and at full speed:
1. Press the top speed button on the LightSense™ fan control, and wait to
allow the fan motor to run up to full speed.
2. Using the controls on the fan (typically pull-chains), adjust so that the fan is
running at full speed, and in the desired direction.
The pull chains may now be removed or shortened.
Button and Paddle Functions
The fan control has a rocker paddle and five speed
control buttons. Use the speed buttons to select an
appropriate fan speed or OFF
Rocker paddle functions are described below.
The fan control may feel warm to the touch during normal operation.
Fan Maintenance
When fan maintenance is required, use the Air Gap Isolation feature for safety.
To activate the feature:
Press
FIRMLY, so that the paddle clicks and
latches in
. Make sure the
status LED is extinguished, indicating that the load is isolated.
To release and return to normal operation, press
.
When you see
touch the
top of the
paddle as
directed.
When you see
touch the
bottom of the
paddle as
directed.
Tap once
Turn fan ON and resume last used speed
Tap twice
Full speed
– –
Press and hold
Increase the speed
Tap once
Turn fan OFF
– –
Press and hold
Decrease the level