INSTALLATION

For ease of installation, Pass & Seymour/Legrand recommends use of a deep

wall box.
1. Disconnect power to circuit by turning circuit breaker OFF before installation.
2. Remove existing wall plate and switch.
3. Strip existing wires

1/2"

.

4. Connect the supply and load ground wires to the GND terminal on the back

of the unit.

5. Connect the white (Neutral) fan control wire to the white supply and load

wires, using a wire nut.

6. Connect the black fan control wire to the black supply Line, using a wire nut.
7. Connect the red fan control wire to the black load wire, using a wire nut.
8. Attach the wall plate.
9. Switch the circuit breaker back ON.

CAUTION

TURN THE POWER OFF AT THE CIRCUIT BREAKER BEFORE

INSTALLING THE DIMMER.