background image

EN

Niky 600/800 

17

Software connection Niky 600/800

The UPS is equipped with a USB interface, thanks to which it is possible by means of a computer 

to access a set of data regarding the operation of the UPS and control the operating system 

unattended shutdown.

Software is available as on option for Win98/ME/2000, Novell and Linux, from the website www.

ups.legrand.com without charge. User license is included in the product.

Telephone protection

The NIKY UPS has an integrated, standard RJ11/RJ45 passing telephone connectionthat provides 

protection for telephone or network equipment (modem, telephones, etc.) against overvoltage

6 Features

Caution

Opening, repairing, or replacing parts inside the UPS must always be carried out by specialized 

technical personnel only. First of all, switch off the UPS with the ON/OFF button located on the 

front panel, then unplug the power cable from the 230V outlet socket.

1)  Switch off the uninterruptible power supply.

2)  Unplug the power cable from the mains socket.

3)  Change the batteries with others of the same type and make, or having the same features

Keep clear from fire to avoid explosion while handling batteries.

Do not open or tamper with the battery case, because it contains toxic electrolyte that could be 

harmful for your skin or eyes. Keep out of children’s reach.

7 Changing batteries

NOTICE 

The batteries must only be replaced by qualified technical personnel, who will dispose of 

them in compliance with the law in force.

Содержание Niky 600

Страница 1: ...800 Index 1 Introduction 14 2 Conditions of use 14 3 Installation 15 4 Signals and controls 15 5 Overload and self shutdown 16 6 Features 16 7 Changing batteries 17 8 Possible malfunctioning 18 9 Technical features 19 ...

Страница 2: ... plug is disconnected there are no parts inside that the user can repair The UPS NIKY has been designed to work in closed clean rooms where there are no inflammable liquids or corrosive substances and where it is not too damp Do not place near equipments that generate strong electro magnetic fields and or near equipments that are sensible to electro magnetic fields engines floppy disks speakers ad...

Страница 3: ... panel has the following meanings Fixed green LED mains present and regular batteries recharging Green LED flashing every 3 sec running on battery Green LED flashing every 0 5 sec autonomy in reserve Green red LEDs flashing test or restart after end of autonomy Fixed red LED failure or battery overload Acoustic signals Intermittent sound every 3 sec running on battery Intermittent sound every 0 5 ...

Страница 4: ...on to provide a reliable operation Battery Protection Automatic battery test and deep discharge protection DC start capability The UPS can be switched on in DC mode battery operation UPS power supplied outlets This is a line interactive UPS equipped with AVR that allows to feed the load with a stabilized output voltage even when mains floats Electrical protection Automatic swith off upon short cir...

Страница 5: ...ures Caution Opening repairing or replacing parts inside the UPS must always be carried out by specialized technical personnel only First of all switch off the UPS with the ON OFF button located on the front panel then unplug the power cable from the 230V outlet socket 1 Switch off the uninterruptible power supply 2 Unplug the power cable from the mains socket 3 Change the batteries with others of...

Страница 6: ... shuts down or immediately signals it is close to the operating limit The UPS has operated with no mains voltage for a long time and has not been able to recharge the battery Recharge it for at least 6 hours by connecting the uninterruptible power supply to the mains The battery is flat due to not using the UPS for a long period Recharge it for at least 6 hours by connecting the uninterruptible po...

Страница 7: ...densing Degree of protection as per IEC529 IP20 Noise level at 1 meter 40 dBA Electrical input specifications Rated input voltage 230 V Range of input voltage from 160 V to 290 V Rated input frequency 50 60 Hz 5Hz Maximum input current 3 75 Arms 5 Arms Number of input phases Single phase Waveform on output With battery operation step wave Type of operation line interactive Electrical specification...

Страница 8: ...tery operation Operating time to 80 of the load 5 min 5 min Charging time 10 12 h at the end of operating range Technical data and number of batteries n 1 maintenance free sealed lead acid battery 12V 7 2 Ah n 1 maintanance free lead acid sealed 12V 9 Ah Standards Electromagnetic compatibility Emission Immunity Conforms to EN 62040 2 Safety Conforms to EN 62040 1 Performance and features Conforms ...

Страница 9: ...elephone fax modem or network protection 4 Output sockets 5 AC Input with AC Fuse 6 USB Serial Interface 9 Technical features SITE WIRING FAULT AC INPUT AC OUTPUT IN OUT 1 1 2 4 5 3 100 09 3 100 10 3 100 02 3 100 03 6 3 100 22 3 100 23 3 4 5 6 3 4 5 6 3 ...

Отзывы: