PIR II User manual - NE41 19003-00 v1.2
11
Radio test alarm
To check the connection with the paired radio unit
PIR II regularly sends a Radio Test alarm.
There is no LED indication when a Radio Test alarm
is sent.
12
Start-up
At start-up the Operation LED (
D2
) blinks green for
45 seconds, where-after it goes fixed green for 1
second and then turns off.
However, if battery is low the Operation LED (
D2
)
blinks red instead of green during the 45 second
start up.
13
DIP switch settings
The settings and functions for the DIP switches are
explained below.
DIP#
Function
ON
OFF
1
Configuration setting
PC
Local
2
Power save mode
Power save
Static
3
IDA function
Yes
No
4
IDA, exit alarm delay
Long
Short
5
IR detection sensitivity
Low
High
6
Operation LED after alarm
Yes
No
7
Detection LED after movement
Yes
No
8
Disable OFF button/Alarm delay
Yes/No delay No/15 s
Table 5. DIP switches (1-8) on PCB.