NOVO Technical Handbook - NE41 15013-02 v2.0
• Changing between Home and Away mode can also be done by some protocols
depending on Alarm Receiver.
When unit exits Away mode and enters Home mode the following occurs:
• The passive function is restarted.
• Radio supervision is restarted.
• Visual indication for Away mode stops.
4.1.3 Presence/Ready
The purpose of Presence mode is to indicate that personnel is present in the user’s
home.
When unit toggles between Presence and Ready it can be configured to transmit
Presence alarm and Ready alarm respectively. If NOVO is configured with
Auto Ready
,
it can instead send the an Auto Ready alarm when resuming Ready mode.
In Presence mode the following is valid:
• If NOVO is so configured it will transmit an
Assistance alarm
when it receives a
User alarm from trigger
or
User alarm from button
.
• Presence mode is indicated by LEDs L1 – L3 flashing On 0.5s/Off3.5s.
• If another visual indication is active, Presence mode indication is inverted.
Exiting Presence mode can be done as follows:
• NOVO receives Presence or Ready alarm type.
• By pressing
Extra button (B3)
, configured to Presence or Ready alarm type.
• By pressing and holding down
Reset button (B2)
while pressing
Alarm button (B1)
twice to toggle between Presence/Ready mode
•
Auto ready
, unit is configured with a
Max time in Presence mode
. When that time
limit is exceeded NOVO will automatically resume
Ready mode
.
When unit exits
Presence mode
and resumes
Ready mode
the following occurs:
• Visual indication for Presence mode stops.
4.2 Technical Alarms
Digitally connected units can be configured to send technical alarms to NEAT
Carephone Management Portal (CMP). This allows continuous supervision of
connectivity and functionality. The descriptions of the technical alarms in the sections
below are valid for alarms sent to an alarm receiver (not the CMP).
4.2.1 Radio transmitter surveillance
Radio transmitters registered in NOVO can be configured to send radio test alarm.
Radio transmitter surveillance can be activated in NOVO for such a transmitter. If
NOVO does not receive radio test alarm for such a transmitter for a configurable
period of time it will trigger a
Radio out of range
alarm.
When a radio test alarm is received from a transmitter previously reported to be out
of range, NOVO can be configured to trigger a
Radio within range
alarm.
Radio transmitter surveillance is paused when unit is in Away mode.