![LEGRAND HC4657M3 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/legrand/hc4657m3/hc4657m3_manual_1870912002.webp)
2
HD4657M3
HD4657M4
HC4657M3
HC4657M4
HS4657M3
HS4657M4
573912
573913
Touch control
MQ00110-f-EN
07/06/2014
1.1 Addressing
Address type
Virtual configuration (MYHOME_Suite)
Physical configuration
Point-to-point
Room
0-10
A=1-9
Lighting point
0-15
PL=0-9
Room
0-10
A=AMB
Group
1-255
A=GR
General
general
A=GEN
Function selection
1. Self-learning mode
NOTE:
With the virtual configuration, for the room, group and general controls, you can set a light
point address for the return of the load status
This mode is available only with the physical configuration. With MYHOME_Suite virtual
configuration you need to associate each button with the specific function. For both modes,
you will have to configure the addresses of the device.
1.2 Configuration
Virtual configuration (MYHOME_Suite)
Physical configuration
Function
Parameter / setting
Associating the buttons on the touch control with the single
commands performed by the control devices and/or actuators
-
1)
M=0
Cyclic self-learning:
This mode is a variant of the self-learning mode (
M=0
), in
which, however, the buttons never work cyclically. So if, for
example, ON is learned for an actuator or dimmer, the pair of
buttons is automatically configured to turn on or increase the
level of brightness for the top button, turn off or decrease the
level of brightness for the bottom one. Whereas, if a single
function is learned (e.g. calling up a scenario), the other button
of the pair will remain without any function or keep the function
it had previously. The device can be configured either with any
A/PL address already in the system or with a unique address not
used by other devices.
-
1)
M=6
NOTE 1):
MYHOME_Suite allows you for each button to define all the operating modes for the
functions: light switch, automation control, scenario module control, programmed scenarios, PLUS
Lighting Management scenario, PLUS programmed scenario, sound system and video door entry
functions.
Installation and destination level:
The special control can also be used in systems where there are SCS/SCS interfaces (F422).
By installing the control on the BUS of an interface (installation level), you can control one
or more actuators located on the BUS of another interface (destination level).
Function
Virtual configuration (MYHOME_Suite)
Physical configuration
Destination level
Local bus
1-15
I= 1-9
Riser bus
riser
I=CEN
Complete system
entire system
I=0
To configure the installation level use MYHOME_Suite virtual configuration.