Switches, powerpoints and other fixed wired products must be installed
by an electrical contractor or similarly qualified person.
25754A
The EM450UP Push Button Dimmer is a solid state device, so there
is still 240V present at the load even when the dimmer is switched off.
Therefore, we recommend that power be switched off at the circuit
breaker before replacing faulty lamps.
Important:
Important:
Important:
When used in ambient temperatures greater than 25°C, the dimmer must be
de-rated according to the following chart.
25
30
35
40
45
50
50
60
70
80
90
100
% Rating
Installation air temperature (ºC)
Warranty
Legrand Cat EM450UP is warranted as here and after appears, against
faulty material and/or workmanship for a period of one year from the
day of purchase. The obligation of the manufacturer under this warranty
is limited to servicing and replacing defective parts when the unit is
returned to the authorised place of purchase, at the purchaser’s cost.
To obtain warranty repair, the purchase receipt should be returned with
the product. This warranty becomes void on any unit which has been
tampered with or damaged by accident, short circuited, loaded beyond
rating or damaged otherwise by improper operation. The warranty
is also conditional on the unit being installed by a licensed electrical
contractor. Our goods come with guarantees that cannot be excluded
under the Australian Consumer Law. You are entitled to a replacement
or refund for a major failure and compensation for any other loss or
damage. You are also entitled to have the goods repaired or replaced
if the goods fail to be of acceptable quality and the failure does not
amount to a major failure.
Troubleshooting
If the dimmer does not turn on and the LED is completely off:
●
Check if the lamps need replacing.
●
If the lamps are ok, then the dimmer’s backup internal fuse may have
blown. This fuse cannot be reset so the dimmer must be replaced.
If the dimmer does not turn on but the LED glows faintly:
●
Short-circuit protection feature is operating.
●
Check the lamps and the wiring for faults.
If the dimmer cannot be dimmed up to maximum brightness:
●
Over-temperature protection is operating.
●
Check that the load is suitable for use with the dimmer.
●
Check that the load is below the maximum rating of the dimmer,
taking into account the number of dimmers per plate and the ambient
temperature.
If the dimmer stays on at full brightness or the lamps flicker
permanently:
●
Check that the load is suitable for use with the dimmer.
●
The dimmer may be permanently damaged and need replacement.
Customer Service
For all Customer Service and Technical Support
please call Monday to Friday during business hours.
HPM Legrand Australia
1300 369 777
www.hpmlegrand.com.au
HPM Legrand New Zealand
0800 476 009
www.hpmlegrand.co.nz
ABN: 31 000 102 661
LED Indicator
● The colour of the LED indicator can be either blue or red. In addition,
when the dimmer is off the LED indicator can either glow faintly or be off
completely. The four possible modes are as follows:
● To change between modes, press and hold the push button for at least
10 seconds. This will select the next mode in the sequence above.
Mode
Status of LED indicator
Dimmer on
Dimmer off
1
Bright blue
Faint blue
2
Bright red
Faint red
3
Bright blue
Off
4
Bright red
Off