background image

 

3

 

 
 
 

 

230 V 

L

 

50 Hz 

N

 

 

  

L

 

  

N

 

N

 

L

 

V1 

To the fan-coil

 

or temperature

 

V2 

control system

 

V3

 

TM2

 

TM1

 

TM3

 

Heating 

  

 

 

Ethernet

 

D

 

Cooling

 

 

 

HUB Switch

 

network

 

GS (TM+EL)

 

Magnet

 

Contact

 

 

Contact

 

 

Magnet 

  

 

 

F430R8

 

E

 

 

 
 
 

1

 

 
 
 
 
 
 
 
 
 

 

DC - In

 

 
 
 

2               3               4               5              6

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Ethernet 

network

 

 
 
 
 
 

 
 
 
 
 
 

MH201

 

 
 
 

 

MH201

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

PRI

 

 

 

To other 

room services

 

 

Protection 

  

 

line 

NC contact

 

ZA     

= 2

 

ZB     

= 7

 

=  1 

LOAD 

= –

 

 

  

ROOM

 

Other rooms

 

 
 
 
 
 
 
 

 

PC for room management

 

E49

 

F

 

 

E49

 

PRI:  220 – 240 V~

 

185 –  175 mA

 

50/60 Hz

 

 

SCS: 27 Vdc

 

600 mA

 

 
 
 
 
 
 
 
 
 
 
 

SCS

 

 
 
 
 

 

WINDOW 
CLOSED

 

 

 

WINDOW 
OPEN

 

 
 
 
 

ON

 

 
 

 

ECO

 

 
 
 
 
 

 

H4691 

LN4691 
0 674 59

 

CORRIDOR

 

 

 

 

 

  RECEPTION

 

 

 
 
 

 

230 Vac    

 

Bell 

12 Vac/dc – 230 Vac

 

max 1A

 

 
 
 
 
 
 
 
 

 

L1  L

 

 
 
 
 

 

Transformer

 

 
 
 

 

H4651 
LN4651

 

 
 
 
 

 

Transformer

 

 
 
 
 
 
 
 

Room door 

electric  lock

 

 
 
 

H4648 
LN4648 
0 675 66

 

5 727 36

 

5 722 36

 

 
 
 

 

H4653 
LN4653 
0 675 93

 

 
 
 

 

DND     MUR

 

 
 
 

 

H4652 
LN4652 
0 675 92

 

 

BUS SCS

 

To other 

devices

 

 
 
 
 

General note: the devices listed in the legend are for 
the LivingLight series.

 

0 675 91

  

 
 

 

348210

 

  

 

2 sec.

 

 

R1   

= 2

 

R2   

= 7

 

M    

=  –

 

  

 

A   

=   9

 

PL  

=  8

 

M  

= CEN

 

F411/1N

 

0 675 89

 

A  

=  1

 

PL 

= 1

 

  

    M 

=  PUL

 

LED 

= –

 

 

B

U

S

 S

C

S

 

R

F

ID

 k

e

y

 c

a

rd

 s

w

it

c

h

e

s

 

0

 6

7

5

 6

6

 

5

 7

2

7

 3

6

 

5

 7

2

2

 3

6

 

H

4

6

4

8

 

L

N

4

6

4

8

 

W

ir

in

g

 d

ia

g

ra

m

s

 

Pr

in

cip

le

 a

nd

 co

n

fig

ur

at

io

n d

ia

gr

am

 fo

r a

 h

ot

el 

ro

om

 

M

M

0

0

7

7

1

-a

-E

N

 

0

2

/1

2

/2

0

1

3

 

 

 

3513

 

 
 
 
 

MODE

 

 
 

+

 

 

 

 

 
 
 

FAN

 

ZA     

= 2

 

ZB     

= 7

 

TYPE 

= 1

 

HEAT 

= 7

 

COOL 

= CEN

 

 

PUMP 

= –

 

IN     

= 3

 

R1   

= 2

 

R2   

= 7

 

M    

=  2

 

L     

=  0

 

A    

=  1

 

PL   

= 1

 

T     

= 2

 

A    

= 9

 

PL   

= 9

 

M1 

= CEN

 

DEL1 

= –

 

M2  

= –

 

DEL2 

= –

 

ITEM

 

DESCRIPTION

 

E49

 

Power supply

 

LN4651

 

Key card reader outside the door and 
indicators

 

348210

 

Key card

 

LN4648

 

Key card switch

 

LN4653

 

DND and MUR controls

 

LN4652

 

8 key scenario control

 

LN4691

 

Thermostat with display

 

MH201

 

IP scenario module

 

F430R8

 

Air conditioning actuator

 

F411/1N

 

DIN module 1 relay actuator

 

A

 

The general switch GS (TM+EL) must 
be selected based on the absorption of 
the services installed.

 

B

 

The TM switch must be selected based 
on the power supply used.

 

C    D

 

The TM switch must be selected based 
on the loads connected.

 

E

 

The actuator to be used depends on 
the type of air conditioning system 
installed.

 

 

F

 

If the current supplied by the E49 
is not sufficient to power the SCS 
system, it is possible to use the 
E46ADCN power supply.

 