LEGRAND 5739 12 Скачать руководство пользователя страница 4

4

The combination of a scenario configured in the scenario programmer 035 65 and the corresponding control activation keys, is performed during the programming of the 
scenario itself with the software supplied.

SPE=0 M=0/I; 

hi

hi

 M  Swivelling modes

Possible function

M configurator value

ON/OFF control:  On control using the upper key, Off control using the lower key. For point-point controls, the ON/OFF functions 
are performed by a quick pressure, while a longer pressure will be used for the adjustments; for the other controls only  
the ON/OFF functions are performed

0/1

Control (UP-DOWN for rolling shutters): up-down control to end of stroke

hi

Monostable control (UP-DOWN for rolling shutters): up-down control for the time the key is pressed

hi

M

These modes enable quick installation without the need for learning or scenario modules, allowing control of 2 consecutive light points or rolling shutters. The A PL address is the light 
point or rolling shutter controlled by the first pair of keys. The subsequent pairs control the subsequent light points or rolling shutters. If the configurator Amb or Gr are connected to 
A, in the same way the 2 pairs of keys control consecutive rooms or groups, starting from the one indicated by the configurator in PL.
The possible A and PL configurations are the following:
- Point-point: A=1 – 9 is the room, PL=1 – 9 is the light point.
- Room: A=AMB, PL=1 – 9 is the no. of the room.
- Group: A=GR, PL=1 – 9 is the no. of the group.
- General: A=GEN, PL=0 all pairs send the same general controls.

Cancel a scenario
1)  The scenario module, item 0035 51 must be in configuration mode with 
  self-learning enabled; 
2)  Press and release the key on the back, the LEDs come on in succession; 
3)  Within 20 seconds press and hold down for 4 seconds the key of the scenario to be 

cancelled;  

4)  The LEDs for the key of the device deleted flash for 4 seconds. Return to item 2 to 

delete other programs. 

5)  Shortly press the relevant key or wait 20 seconds to exit the deleting mode;

NOTE:

 the entire memory can only be reset from the scenario module: press and hold 

down the "DEL" key for 10 seconds after enabling programming on the scenario module.

SPE=0 M=CEN Scenario programmer mode

Possible function

M configurator value

Always assign to the control a specific A/PL address on the system (not to be used by any other device installed on the Bus), A=0 
– 9, PL=0 – 9. 
The A=0, PL=0 configuration cannot be accepted. This operating mode can only be used if the system includes a scenario 
programmer (035 65). 

CEN

DEL

035 51

Programming a scenario
1)  The self-learning configuration of the scenario module, item 0035 51, must be 

enabled (to do so press the self-learning pushbutton so that the corresponding 
LED turns green; if the LED is red, self-learning is disabled);

2)  Press and release the key on the back; the LEDs of the keys enabled and pro-

grammed for the scenario function will flash (1 sec. on and 1 sec. off);

3)  Quickly press the key corresponding to the scenario to be programmed: the LED 

will start flashing (upon receiving the update of the scenario module), confirming 
that the programming mode is active.

4)  Set the scenario using the corresponding controls and/or actuators.
5)  Press the pushbutton to exit programming: the LEDs flash in succession, it is now 

possible to repeat points 2, 3 and 4 for all scenarios, including those keys that 
have already been associated, if they need changing.

6)  Press the pushbutton on the back to exit programming, or wait 20 seconds to exit 

programming automatically.

035 51

Scenario reset 

pushbutton

 Scenarios/learning reset 

LED

Lock/unlock programming 

pushbutton

Programming status LED

LG00047-c-UK

5739 12

5739 13

Отзывы: