NOTE: To cancel the programming of all keys at the same time press and release the
key on the back. The LEDs will come on in succession. Press the pushbutton on the
back again, and hold it down for 10 seconds: all LEDs will flash for about 4 second to
confirm that all programming has been deleted.
Deleting the programming of the keys
1) Press and release the key on the back, the LEDs come on in succession;
2) Within 20 seconds press and hold down for 4 seconds the key for which
programming is to be cancelled; from now on, the key will no longer activate any
controls until reprogrammed;
3) the corresponding LED flashes for 4 seconds in alternative to the others, after
which it will be possible to repeat point 2, to delete other programming sequences;
4) quickly press the pushbutton, or wait 20 seconds to automatically exit delete
programming.
Non cyclic self-learning mode M=6
Scenario mode M=1 – 4
Possible function
M configurator value
This mode is a variant of the self-learning mode (M=0), where, however, the keys never work cyclically. Therefore if, for example,
the ON of an actuator or dimmer is learnt, the couple of keys is configured automatically to switch on or increase the light intensity
level for the upper key, and switch off or decrease the level of intensity for the lower one. If, on the other hand, the single function
is learnt (e.g. recalling of a scenario), the other key of the pair remains without function, or retains the previous function. The display
may be configured using any A/PL address already present in the system, or a unique address not used by other devices.
6
Possible function
M configurator value
This operating mode is useful if the system includes a scenario module, item 0035 51. The combination is ensured by assigning to both
items the same address, identified by A=0-9 and PL=1-9. The user may create, delete or change the scenarios saved in the scenario
module, and can recall them using the keys. With this procedure it is possible to save up to 16 scenarios using three 6-key devices.
1 – 4
The following table shows the correspondence between the number of the scenario saved in the scenario module, and the keys of the
control in the possible configurations: 3 module control (6 sensors)
Number of the key
M=1
M=4
M=3
Key 1
scenario 1
scenario 7
scenario 13
Key 2
scenario 2
scenario 8
scenario 14
Key 3
scenario 3
scenario 9
scenario 15
Key 4
scenario 4
scenario 10
scenario 16
Key 5
scenario 5
scenario 11
Key 6
scenario 6
scenario 12