9. MAINTENANCE

Keep the lens clean.
Clean the surface with a cloth.
Do not use: acetone, tar-removing cleaning agents or trichloroethylene.
Maintenance with the following products:  - Hexane (En 60669-1), 

- Methylated spirit, 
- Soapy water, 
- Diluted ammonia, 
- Bleach diluted to 10%, 
- Window-cleaning products. 

10. STANDARDS

Directive: CE
Installation standards: NFC 15-100
Product standards: IEC 60669-2-1
Environmental standards: 
-  EU Directive 2002/96/EC: 

WEEE (Waste Electrical and Electronic Equipment)

-  EU Directive 2002/95/EC: 

RoHS (Restriction of Hazardous Substances)

- Regulations:  ERP (public buildings) 

ERT (workplace buildings) 
IGH (high-rise buildings)

ATTENTION:  An initial test is required for the use of other special 

maintenance products.

8. PERFORMANCE

Ø 

Sensitivity
Low (25%)

Sensitivity

Medium (50%)

Ø (m)

Surface (m

2

)

Ø (m)

Surface (m

2

)

Height (m)

2.5

4

15

4

15

3

6

30

6

30

4

6

30

6

30

5

6

30

6

30

6

0

0

6

30

Sensitivity

High (75%)

Sensitivity

Very high (100%)

Ø (m)

Surface (m

2

)

Ø (m)

Surface (m

2

)

Height (m)

2.5

6

30

11

95

3

8

50

13

150

4

10

80

13

150

5

10

80

13

130

6

10

80

13

130

Height

Содержание 488 21

Страница 1: ...en detector and actuator RJ 45 lead or cable or BUS SCS cable to be fitted with RJ 45 connector Fitting diameter 65 mm without fitting unit 68 mm with fitting unit Weight 140 g Impact resistance IK04 Penetration by solid and liquid matter IP20 Usage temperature 5ºC to 45ºC Storage temperature 20ºC to 70ºC Cover removed CONTENTS Page 1 Use 1 2 Technical features 1 3 Overall dimensions 1 4 Connectio...

Страница 2: ... 08 2010 Created on 20 05 2010 2 4 CONTENTS 5 INSTALLATION 6 DISASSEMBLY 1 2 3 1 2 50 0 3 to 30 mm Ø 68 Ø 65 4 CONNECTION Type of terminals RJ 45 RJ 45 RJ 45 patch and equipment cords RJ 45 BUS SCS connector RJ 45 doubler Option It is possible to manage the detector by infra red remote control ...

Страница 3: ...short period the LED flashes slowly 2nd press Keep LEARN pressed down for 10 seconds until the LED flashes quickly 7 SETTINGS Parameters Time delay Length of time the load is on after a detection is made Sensitivity Detection range setting Light level threshold Value at which the load comes on if light is less than the setting and goes off if it is above this threshold Auto on Auto off mode Comes ...

Страница 4: ...roduct standards IEC 60669 2 1 Environmental standards EU Directive 2002 96 EC WEEE Waste Electrical and Electronic Equipment EU Directive 2002 95 EC RoHS Restriction of Hazardous Substances Regulations ERP public buildings ERT workplace buildings IGH high rise buildings ATTENTION An initial test is required for the use of other special maintenance products 8 PERFORMANCE Ø Sensitivity Low 25 Sensi...

Отзывы: