9
3 Operation
3.1 Boot Up and Shut Down
Boot up
Connect the NVS to the power and then press the power button in the front panel. You can see the power indication light becomes on
and NVS boots up.
The system is in multiple-window display mode by default.
Shut down
You can press power button in the front panel for three seconds to shut down the device.
System Restore after Power Failure
When decoder is working, if the power failure occurs, the system can automatically connect to the front-end device and restore
previous working status once the power connection becomes normal.
3.2 Login
3.2.1
Preparation
Before log in, please make sure:
NVS connection is OK.
You have set PC IP address, NVS IP address, subnet mask and gateway. (Please set the IP address of the same section for the PC
and NVS. Please input corresponding gateway and subnet mask if there are routers.) When NVS booted up normally, please input
account name
admin
and password
admin
via the PC COM port., then input net
–a and then input IP, NETMASK, GATEWAY. The
command mode is: net -a [IP] [NETMASDK] [GATEWAY].
For example:
Username: admin
Password: admin
DeBug>net -a 192.168.XXX.XXX 255.255.XXX.XXX 192.168.XXX.XXX
Use order ping ***.***.***.***(NVS IP address) to check connection is OK or not. Usually the return TTL value should be less than 255.
Open IE and then input the address in the column.
WEB control can be downloaded and installed automatically. System can download the latest Web control and remove the old one.
You can run uninstall web.bat to remove the control
System is compatible with web control of W INVISTA. But you need to disable account control item and then reboot the PC.