24
Please refer to the following sheet for detailed information.
Parameter
Function
Event Type
It includes local alarm/network alarm.
Local alarm: Device detects alarm from input port.
Network: Device detects alarm from network.
Alarm in
Select corresponding alarm channel.
Enable
You need to draw a circle here so that system can detect the alarm signal.
Type
There are two options: normal open and normal close. NO becomes activated in
low voltage, NC becomes activated in high voltage.
Period
Alarm record function becomes activated in the specified periods.
There are six periods in one day. Please draw a circle to enable corresponding
period.
Select date. If you do not select, current setup applies to today only. You can
select all week column to apply to the whole week.
Click OK button, system goes back to alarm setup interface, please click save
button to exit.
Anti-dither
System only memorizes one event during the anti-dither period. The value ranges
from 0 to 15s.
Normal Out
Enable alarm activation function. You need to select alarm output port so that
system can activate corresponding alarm device when alarm occurs.
Alarm Latch
System can delay the alarm output for specified time after alarm
ended. The value ranges from 10 seconds to 300 seconds.
Tour
Display the selected video in local monitor window.
Copy
It is a shortcut menu button. You can copy current channel setup to one or more
(all) channels.
Save
You can click save button after you complete setup for one channel, or you can
complete the whole setups and then click save button.
Refresh
Click this button to get device latest configuration information.