1.
Modular Coal Set
- The ceramic coals supplied with this appliance can be replaced at service intervals
depending on their condition. If the coals do require replacement, the consumer can do so provided that the
Ceramic Component Layout Instructions (pages 12-15) are adhered to. Under no circumstances should
additional/extra coals be added. Only genuine Legend replacement parts should be used.
Order Ref:
EVCS01
2.
Oxygen Depletion Sensing Pilot
- In the unlikely event of a pilot failure, the pilot assembly should only be
replaced by a
Gas Safe Registered Engineer
. The user must not carry out this work.
Order Ref:
LEG62
3.
Control Tap
- In the unlikely event of control tap failure, the assembly should only be replaced by a
Gas Safe
Registered Engineer
. The user must not carry out this work.
Order Ref:
LEG61
4.
Glass Panel
- Should the glass become cracked or broken, the fire should not be used under any
circumstance.
Order Ref:
LEG59
5.
Glass Rope Seal
- The integrity of the glass rope seal should be checked on service and replaced if
necessary by a
Gas Safe Registered Engineer
.
Order Ref:
LEG58
COMMISSIONING
7
Gas Type
Natural Gas (G20) Cat
I
2H
Gas Connection
8mm
Number of Injectors
One
Injector size
Stereomatic 1.70mm
Control Max Operating Temperature
80
o
c
Inlet Pressure Cold
20 mbar
Heat Input (Gross)
4.6 kW (Full)
3.0 kW (Reduced)
Weight
10.4 kg
NOx Level
Class 5
REPLACEMENT PARTS
TECHNICAL DATA
1. Unscrew the inlet pressure test point sealing screw
(Fig. 7) and fit a manometer. Consult the user instructions (page 9). Ignite the appliance and turn to the high
position.
2. Take a pressure reading and consult the technical data (page 7) to establish
the correct working pressure.
3. Once the pressure has been checked and verified, turn off the appliance.
Consult the ceramic component set up diagrams
(pages 12-15) and fit the ceramics as per the instructions.
4. Re-install glass panel. The glass should be positioned centrally to ensure
the decorative trim will fit over it.
5. Carry out a Spillage Test (page 4)..
Inlet Pressure
Test Point