INSTALLATION PROCEDURE 

CONTINUED

6

Radiant box

Hearth

Eye Bolts

Centre Line

Drill Holes for 4 eye bolts

on 112mm centre lines

between max and min height.

65mm

min

Fix the radiant box into the opening, securing into position using the cable fixing kit (Fig. 6). Do not cut off the
loose ends as the full length is required should the radiant box need refitting at any time. Coil up and securely
store underneath the burner tray.

1. Position the burner tray into the box in order to determine the length of 8mm gas supply needed and cut to
length.

2. Before making the final connection, thoroughly purge the supply pipe to clear any foreign matter, i.e. masonry
dust etc, as this could lead to blockages in the control valve and/or pilot assemblies.

3. Fix the burner in place using the four screws and make the gas connection. Carry out a gas soundness test. 

ALTERNATIVE FIXING METHOD

Where the drilling of the back panel is not practical, an alternative 
fixing method may be employed using the 

optional

cable fixing kit 

provided. Drill four holes in the rear of the fireplace opening (Fig. 5). 
Securely fix the four eye bolts provided using suitable rawl plugs. 
Feed one cable through each of the top holes in the rear of the 
fire box.

115mm

max

500mm

min

550mm

max

112mm

112mm

Tension Nut

Cable Clamping Screw

Fig. 5

Fig. 6

Cable

Rectangular
Cutout

Insert cable into rectangular cutout
and feed the end back through the
small hole above the cutout.

Fixing
Holes

Fixing
Holes

Fixing  Holes

9. When the burner tray has been removed, decide which
side of the appliance the gas supply will be entering the
radiant box and remove the relevant blanking plate. The
gas supply should be concealed as much as possible. Both
blanking plates 

MUST

be re-fitted or this could seriously

impair performance.

10. With the radiant box placed in the opening, mark out
four of the eight fixing holes. Remove the box and carefully
drill and fit rawl plugs.

11. Pass the 8mm gas connection through the back of the 
box and secure the box into place using four screws 
(straight shank screws are recommended for marble). 
Check that the outer flange of the appliance is completely 
sealed against the back panel.

Fig. 4

Содержание Evora

Страница 1: ...llation and then should be handed to the end user when the installation is complete This is an official requirement and is the responsibility of the fitter of this appliance Having installed the appliance the installer should take the necessary steps to ensure that the user fully understands how to operate the appliance and is also made aware of the fire s basic cleaning and maintenance requiremen...

Страница 2: ...ure 5 Commissioning 7 Technical Data 7 Replacement Parts 7 Trouble Shooting GAS SAFE Engineer Only 8 User Instructions 9 Cleaning and Maintenance 10 Fire Front Specifications 11 Modular Coal Layout Instructions 12 Modular Pebble Layout Instructions 14 Guarantee 16 Trouble Shooting User 16 CONTENTS 2 ...

Страница 3: ...peration The installer must then establish that all the products of combustion are entering the flue within ten minutes of lighting from cold This can be verified by inserting a lit smoke match into the left and right hand ducts immediately above the glass retaing strip It should NOT be inserted into the central convector duct This operation should be carried out before fitting the trim and louvre...

Страница 4: ...eness of the flue and to ensure that there is no leakage into another part of the premises including any loft or as appropriate other adjoining premises this is particularly important where a number of chimneys combine into a multiple stack The flue flow test should be carried out using a suitable smoke pellet which the pellet manufacturer claims to generate 5m3 of smoke in 30 seconds burn time Th...

Страница 5: ...e radiant box When the box is placed against a flat surface the foam strip will form a seal around the boxes flange 7 Carefully lift the appliance into position in the fireplace opening and check that the flange of the radiant box fits flush against the sealing face with no gaps present 8 Remove the five screws that secure the burner tray to the box two on the front leg two at the rear of the tray...

Страница 6: ... optional cable fixing kit provided Drill four holes in the rear of the fireplace opening Fig 5 Securely fix the four eye bolts provided using suitable rawl plugs Feed one cable through each of the top holes in the rear of the fire box 115mm max 500mm min 550mm max 112mm 112mm Tension Nut Cable Clamping Screw Fig 5 Fig 6 Cable Rectangular Cutout Insert cable into rectangular cutout and feed the en...

Страница 7: ...der Ref LEG59 5 Glass Rope Seal The integrity of the glass rope seal should be checked on service and replaced if necessary by a Gas Safe Registered Engineer Order Ref LEG58 COMMISSIONING 7 Gas Type Natural Gas G20 Cat I2H Gas Connection 8mm Number of Injectors One Injector size Stereomatic 1 70mm Control Max Operating Temperature 80oc Inlet Pressure Cold 20 mbar Heat Input Gross 4 6 kW Full 3 0 k...

Страница 8: ...he coal set as per Ceramic Component Layout Instructions pages 12 15 5 The fire makes a roaring noise when lit Check That the front coal is seated correctly and the pilot hole is positioned correctly over the pilot assembly IF ANY PART OF THE PILOT ASSEMBLY IS SUSPECTED AS BEING FAULTY THE COMPONENT MUST BE REPLACED 6 The flames appear blue after the fire has fully warmed up The coals ceramic line...

Страница 9: ...o the top position NOTE The pilot assembly fitted to this appliance has an oxygen depletion sensor built in to monitor the room for products of combustion If the sensor should operate and switches the appliance off re ignite the appliance following the procedure above Should the appliance repeatedly activate the sensor a specialist should be called to inspect the appliance 7 The fire must always b...

Страница 10: ...trip and the pilot assembly Any build up of debris in this area could affect the operation of the appliance Fig 11 NOTE It is common to find surface cracks in the ceramic components This is due to the expansion and contraction of the ceramic fibres caused by the intense heat that the burner generates The cracks will not affect the safe operation of this appliance However great care must be taken w...

Страница 11: ...e use of a fireguard confirming to BS 6539 such that the approach to the naked flame is minimised CLEANING AND MAINTENANCE CONTINUED 11 w Y X Minimum area free space 15cm2 Minimum area free space 5cm2 Fig 12 Slide Control Lever The slide control mechanism should be greased annually with high temperature grease Place a small amount of grease at the top and bottom of the lever guide and operate the ...

Страница 12: ...that the back edge is pushed up against the front of the burner strip Fig 15 CAUTION The coals are extremely fragile and must be handled accordingly Gloves should be worn and any inhalation of dust should be avoided The coals must be kept away from children at all times Never put additional coals on the fire Never use coals other than those originally supplied or genuine Legend Spare Parts Fig 13 ...

Страница 13: ...r to achieve the desired flame picture It may be necessary to remove some or all of the coals to clean them at some time Cleaning must only be done using a soft brush 5 Finally check that all the coal pieces are nested together correctly Fig 18 and a close fit is achieved on the middle joint this will stop gas surge through the gap ...

Страница 14: ...t the back edge is pushed up against the front of the burner strip Fig 21 CAUTION The pebbles are extremely fragile and must be handled accordingly Gloves should be worn and any inhalation of dust should be avoided The pebbles must be kept away from children at all times Never put additional pebbles on the fire Never use pebbles other than those originally supplied or genuine Legend Spare Parts Fi...

Страница 15: ...r to achieve the desired flame picture It may be necessary to remove some or all of the pebbles to clean them at some time Cleaning must only be done using a soft brush 5 Finally check that all the pebble pieces are nested together correctly Fig 24 and a close fit is achieved on the middle joint this will stop gas surge through the gap ...

Страница 16: ...emove all the loose coals and the front coal and thoroughly clean any debris in and around the pilot area If the fire will still not light contact your installer 2 The flames appear blue excessive soot deposits The ceramic components including the coal need relaying pages 12 15 Too much or too little room ventilation Seek professional advice 3 Roaring noise coming from the pilot The front coal is ...

Отзывы: