How the PHD 200 works
The PHD 200 refrigerant dehumidifier uses a fan to draw
moist air in and condenses it into water that collects in a
tray and is automatically pumped out through a drain
hose.
The PHD 200 is preset to automatically maintain a 50%
RH level. To change this setting, see “Humidistat Mode”
below. Note: Unit automatically shuts off below 40% RH.
CONTROLS AND OPERATING
INSTRUCTIONS
Set unit upright
NOTICE: Always store, transport, and use the unit in
a horizontal position. If the unit is ever placed in a
vertical position, return it to the horizontal position
and let it stand for at least 30 minutes before turning
it on.
Positioning a Dehumidifier
For best results, operate your dehumidifiers in an en-
closed area. Place your dehumidifier away from obstruc-
tions, and keep it away from anything that could block
airflow into and out of the unit. For more information
about creating an optimum drying environment, contact
Legend Brands at 800-932-3030.
TIP: Before installing in a crawlspace or other difficult to
access location, plug in the unit and run it for approxi-
mately half an hour to ensure proper operation.
Set up drain hose
The PHD 200 condensate pump connects to a plastic
drain hose equipped with a quick-connect fitting for quick
attachment to the unit. To set up the hose, unwrap the
entire hose and place the unattached end in a sink,
drain, bucket or outdoors
– anywhere that water can
drain out safely. Connect the other end of the hose to
the PHD 200. If you use a bucket or other container for
water collection, check it regularly to prevent overflows.
NOTICE:
Uncoil and straighten the entire drain hose. Do
not leave any part of the hose coiled and do not place
the end of the hose higher than 3 ft. (1 m) above the bot-
tom of the unit. Also check for kinks or other obstructions
that might restrict the flow of water. Obstructions may
cause a water backup and result in overflows.
Plug in electrical cord
The PHD 200 should be plugged into a GFCI-protected
115 volt outlet rated for at least 15
amps. Always plug
the cord firmly into the unit first, and then plug the other
end into a suitable outlet.
Startup display and normal display modes
When unit is first plugged in to AC power, the control
panel display will briefly cycle through a series of
readouts. This is part of the unit’s self-diagnosis proce-
dure and no user intervention is required.
Turn the unit on
The control panel on the PHD 200 dehumidifier has a
display and a touchpad with four keys. Press the
ON/OFF
to turn the unit on. The unit will now go
through a compressor delay countdown (up to sixty sec-
onds in duration) and a self-diagnostics process.
Once the compressor delay countdown and self-diag-
nostics are complete, the display will switch to
normal
display mode
.
HUMIDISTAT
INLET 00°F / INLET 00%
The
first line
of the display shows the total number of
hours the unit has been in operation. This value may be
reset to zero to track job hours (see “Job Hours Reset”
below). The
second line
of the display alternates be-
tween inlet temperature and inlet humidity.
Fig. A: Parts Identification
Condensate
drain quick-
connect
Air inlet
Control
panel
Air outlet
Power
socket
Remove/Insert
air filter here.
Temp/RH
sensor