110485K (07-01839) F413
5
Legend Brands, Inc.
damage this equipment and may create a hazardous
condition or void warranty.
•
Do not expose the control panel to moisture, snow
or rain.
•
Protect from freezing.
•
Store and transport securely to avoid any damaging
impact to internal parts.
•
Secure during transport to prevent sliding and possi-
ble injury to vehicle occupants.
MAINTENANCE SCHEDULE
WARNING! ELECTRIC SHOCK HAZARD.
Unplug unit
before cleaning or servicing
.
WARNING:
Risk of dust and contaminants exposure.
Use of respirator mask and gloves is recommended. If
unit has been exposed to potentially dangerous contami-
nants, clean thoroughly and sanitize before reuse.
NOTICE:
The unit is fitted with sensitive electronic sen-
sors. Protect the sensors and their lead wires from dam-
age and do not expose them to water or cleaning solu-
tion.
The following tools and supplies are needed to com-
plete the maintenance procedures described in this
manual:
Philips screwdriver
10 mm wrench
6 mm hex bit
¼ in. nut driver
Cleaning cloths
HEPA vacuum cleaner with soft brush nozzle and
crevice nozzle.
Recommended
Cordless drill, small knife, small-jaw pliers, coil clean-
ing solution, rotomolded housing cleaning solution.
Before each use
Inspect the electrical cord for damage.
Look for fray-
ing, cuts, etc. If you find any damage, replace the cord
with an authorized Legend Brands part.
Inspect filter.
Replace if accumulation of dust and de-
bris is visible.
NOTICE: Replace used filters only with a new Dri-Eaz
4-PRO filter part no. #102312 (F583) (24-pack). Other fil-
ter types do not provide adequate filtration or airflow.
Each filter is individually wrapped to protect filtration ef-
fectiveness. Remove the wrapper before installing the fil-
ter into the dehumidifier.
Monthly
Inspect coils
. Clean when dust accumulation is visible.
In normal use, dust can accumulate and can restrict air-
flow, reducing performance and causing the unit to over-
heat. Use a vacuum cleaner with a brush tool and a soft
cloth to remove any debris. Take care not to damage
any interior components.
To maintain appearance
, wipe interior and exterior sur-
faces with a damp cloth. For deep cleaning and a last-
ing, protective shine, use an automotive interior cleaner.
As Needed
Clean pump check valve and basin.
Remove grills and
cover as shown in Fig. B. Remove screws from pump
base and lift out pump. Wipe out pump basin with a
damp cloth. Inspect the pump base for build-up of debris
and clean if needed. Unthread barbed fitting with check
valve and rinse fitting and check valve with clean water.
Reinstall check valve into barbed fitting and install the
barbed fitting into pump. Do not overtighten. Reinstall
pump on base. Reinstall cover and grills.
Clean coils.
With the cover removed, inspect both coils.
If excessive dust and debris is present, vacuum thor-
oughly and/or clean with coil cleaner.
Remove the 4 screws
from housing and 2
top screws each from
inlet and outlet grills
and lift off cover.
Fig. B: Disassembly for Cleaning