DEFINITIONS FOR ILLUMINATED LED INDICATORS
Power
On
Wiring
Fault
Using
Battery
Circuit
Breaker
Alarm
Condition
On
Off
Off
Set
Off
Normal
Off
On/Off
On
Set
Two
Beeps
Utility Failure- The UPS is providing battery power
to the Battery-Power Supplied outlets.
Off
On/Off
On
Set
Rapid
Beeps
Utility Failure- The UPS is providing battery power.
The rapid beeps indicate the battery will run out of
charge within a few minutes.
Off
Off
On
Up
Two
beeps
or
rapid
beeps
Overload- Occurs in the Full-time Surge Protection
Outlets. Turn the UPS off and unplug at least one
piece of equipment from the UPS. Wait 5
seconds, reset the circuit breaker and turn the
UPS on.
Off
On/Off
On/Off
Set
Long
Beep
Overload- Occurs in the Battery-power Supplied
Outlets. Turn the UPS off and unplug at least one
piece of equipment from the UPS. Wait 5
seconds, reset the circuit breaker and turn the
UPS on.
On/Off
On
On/Off
Set/Up
None
Electrical Wiring Fault- This indicates a wiring a
problem such as a bad ground, missed ground or
reversed wiring within the AC outlet. User is
advised to disconnect all electrical equipment from
the outlet and have the outlet checked by an
electrician.
8