background image

 

 

 

DEFINITIONS FOR ILLUMINATED LED INDICATORS 

 

 

 

Power 

On 

 

Wiring 

Fault 

 

Using 

Battery 

 

Circuit 

Breaker 

 

 

Alarm 

 

Condition 

On 

Off 

Off 

Set 

Off 

Normal 

Off 

On/Off 

On 

Set 

Two 
Beeps 

Utility Failure- The UPS is providing battery power 
to the Battery-Power Supplied outlets. 

Off 

On/Off 

On 

Set 

Rapid 
Beeps 

Utility Failure- The UPS is providing battery power.   
The rapid beeps indicate the battery will run out of 
charge within a few minutes. 

Off 

Off 

On 

Up 

Two 
beeps 
or 
rapid 
beeps 

Overload- Occurs in the Full-time Surge Protection 
Outlets.    Turn the UPS off and unplug at least one 
piece  of  equipment  from  the  UPS.    Wait  5 
seconds,  reset  the  circuit  breaker  and  turn  the 
UPS on. 

Off 

On/Off 

On/Off 

Set 

Long 
Beep 

Overload-  Occurs  in  the  Battery-power  Supplied 
Outlets. Turn the UPS off and unplug at least one 
piece  of  equipment  from  the  UPS.    Wait  5 
seconds,  reset  the  circuit  breaker  and  turn  the 
UPS on. 

On/Off 

On 

On/Off 

Set/Up 

None 

Electrical  Wiring  Fault-  This  indicates  a  wiring  a 
problem such as a bad ground, missed ground or 
reversed  wiring  within  the  AC  outlet.    User  is 
advised to disconnect all electrical equipment from 
the  outlet  and  have  the  outlet  checked  by  an 
electrician. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание Legend SB825

Страница 1: ...User s Manual Legend SB825 UPS K01 1120009 00...

Страница 2: ...ED LED INDICATORS 8 LIMITED WARRANTY 8 Thank you for purchasing a Legacy Power Conversion Product To enjoy all the features and benefits of this Uninterruptible Power System UPS please read and follow...

Страница 3: ...rcumstance that would affect operation or safety of any life support equipment with any medical applications or patient care CAUTION The battery can energize hazardous live parts inside even when the...

Страница 4: ...demand of your connected equipment cannot exceed the maximum total power rating of your UPS 2 Connect your UPS power cord into a two pole three wire grounding receptacle only Please avoid using extens...

Страница 5: ...on against surges and spikes Surge Protection Outlets Provides three surge protected only outlets for connected equipment Circuit Breaker Reset for Overload Protection Resetable circuit breakers provi...

Страница 6: ...is harmful to the skin and eyes and may be toxic CAUTION A battery can present a high risk of short circuit current and electrical shock Take the following precautions before replacing the battery 1...

Страница 7: ...ensure the UPS performs expected runtime REMINDER Batteries are considered HAZARDOUS WASTE and must be disposed of properly Contact your local government for more information about proper disposal and...

Страница 8: ...0 859 5711 Circuit breaker is tripped due to overload Turn the UPS off and unplug at least one piece of equipment Wait 10 seconds reset the circuit breaker and then turn the UPS on Batteries are disch...

Страница 9: ...ction and Filtering Lightning Surge Protection Yes Internet Ready DSL Phone FAX Modem Protection RJ11 RJ45 One In One Out Physical Total of UPS Receptacles 6 Maximum Dimensions 28 3cm x 9 1cm x 16 4cm...

Страница 10: ...the Full time Surge Protection Outlets Turn the UPS off and unplug at least one piece of equipment from the UPS Wait 5 seconds reset the circuit breaker and turn the UPS on Off On Off On Off Set Long...

Страница 11: ...tial Customer of the Product and therefore entitled coverage under the Limited Warranty Registration is not required for Limited Warranty coverage but note if you do not complete a registration card y...

Страница 12: ...within a reasonable time Legacy will refund to you the full purchase price you paid for the Product purchase receipt showing price paid is required CONDITIONS TO THE LIMITED WARRANTY The Limited Warra...

Страница 13: ...s even though damage or loss is caused by negligence or other fault NOTE Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitatio...

Страница 14: ...ween the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician fo...

Отзывы: