Lefroy Brooks CT 8700 Скачать руководство пользователя страница 15

15

DOs

DON’Ts

• Check all joints and connections.
• Ensure that the ‘safe temperature’ has been set.
• Ensure the black plastic ‘temperature stop’ has 

been fitted to avoid damage to the thermostatic 
cartridge and enable the ‘safe temperature’ to 
be operational.

• Ensure that the thermostatic valve, connected 

controls and outlets work satisfactory.

• Instruct the customer how to override the ‘safe 

temperature’ setting. Also ensure the customer 
knows the dangers of overriding the setting and 
understands that the override control is to be 
returned to the ‘safe temperature’ setting after 
use.

• Hand these instructions along with the cleaning 

leaflet to the customer.

• Ensure that the valve is suitably protected 

from damage and decorating materials during 
installation.

• Do not use excessive force when turning 

the thermostatic cartridge spindle. This will 
damage the cartridge. To avoid damage, when 
setting the ‘safe temperature’ the thermostatic 
cartridge spindle must be turned by hand only. 
The spindle will require only minor adjustment. 

Turning the spindle to the end of its travel and 
forcing it beyond this point will cause internal 
damage to the thermostatic cartridge.

 

Содержание CT 8700

Страница 1: ...CT 8700 MK 8700 EXPOSED THERMOSTATIC SHOWER VALVE WITH CERAMIC LEVER INSTALLATION GUIDE...

Страница 2: ...O K S M A D E I N E N G L A N D H O T C O L D MADE IN L E F R O Y BROOKS L I M I T E D E N G L A N D 50mm 105mm 33mm 107mm 90mm 15mm Copper 153mm Connaught CT 148mm Mackintosh MK COLD HOT 200mm G 2 D...

Страница 3: ...1085mm maximum CT MK 8702 CT MK 8720 CT MK 8703 CT MK 8705 All dimensions are taken from centres HOT COLD HOT COLD 200mm 200mm Note On 8720 the hot is on the right and cold on the left HOT COLD HOT C...

Страница 4: ...ermostatic cartridge cover PTS025 MK Handwheel PTS020 Lock washer PTS022 Temperature stop LB2750 Thermostatic cartridge PTS021 Lock nut PTS007 Screw PTS004 White lever UPPER ceramic only PTE016 Black...

Страница 5: ...ICAL FLOW RATES Note Balanced pressures shown are applied directly to the hot and cold inlets flow rates indicated are free flowing and may vary subject to restrictions created by installation pipewor...

Страница 6: ...tridge replacing the non return valve sections Time between servicing can vary as it is subject to usage and water quality Servicing kits are available reference code PTE021 or refer to exploded view...

Страница 7: ...he external joints For this reason we recommend that all connections to and from the valve are pressure tested Access It is important to leave suitable clearance and access to the valve and connection...

Страница 8: ...the cartridge spline whilst measuring the temperature of the water Ideally the temperature measurement should be taken using a digital thermometer Duty of care Legislation dictates recommendations an...

Страница 9: ...rtridge spline with the safe temperature locator in a horizontal or slightly lower position This is dependent on the orientation of the splines as shown above Do not set higher as this will effect the...

Страница 10: ...perature Maximum temperature Set horizontal or slightly higher Minimum temperature Maximum temperature button alignment button alignment button alignment Safe temperature button set to top suitable fo...

Страница 11: ...ontrol handwheel A by unscrewing set screw B using a 1 5mm hexagonal key 2 Remove the override C and temperature stop D by unscrewing and removing screw E Fitting handwheel A and set screw B will aid...

Страница 12: ...temperature by following the setting instruction in the setting safe temperature section Check the water temperature with a thermometer 1 Once the key setting points have been aligned and o rings L f...

Страница 13: ...um screw N in a counterclockwise direction Gently pull the lever from the cartridge spline 2 Remove the cartridge cover P by unscrewing set screw Q using a 1 5mm hexagonal key We recommend wearing a r...

Страница 14: ...thermostatic valve Unscrew the two collar nuts in a counterclockwise direction This will release the thermostatic valve from the mounting surface 3 Unscrew the elbow assemblies from the sides of the t...

Страница 15: ...understands that the override control is to be returned to the safe temperature setting after use Hand these instructions along with the cleaning leaflet to the customer Ensure that the valve is suita...

Страница 16: ...ct to licence or agreement with LBIP Ltd The design registrations trademark registrations and copyrights are protected by law and the use or reproduction outside the terms of an agreement is prohibite...

Отзывы: