LEDVANCE LMS Sensor Value Infrared
black
score dimension 148 x 210 mm
2
Product Features:
a. Infrared motion sensor with integrated photocell sensing function can help to save power consumption via turn
on and turn off the power according to its setting; It detects human motion within its detection range.
b. Infrared motion sensor cannot receive the induction if there is glass, wood or metal materials in between within
detection range;
c. Selectable time delay period from 10 seconds to 15 minutes via knob switch;
d. Selectable daylight sensing level from 3 lux to 2000 lux via knob switch.
Product Specification:
a. Detection method: Infrared motion sensor with photocell integrated
b. Ambient temperature: -20~+40°C
c. Power Input: 220-240V/AC
d. Input Frequency: 50/60Hz
e. Detection Range: 360°
f. Installing Height: 2.2~4m
g. Ambient Light (Selectable): <10-2000LUX
h. Time-Delay (Selectable):
• Min.:10sec±3sec;
• Max.:15min±3min;
i. Nominal Power Consumption: 0.9W
j. Transmission Power: <10mW
k. Maximum Rated Load:
• 1200W (incandescent lamp)
• 300W (energy-saving / led-lamp)
l. Detection Motion Speed: 0.6~1.5m/s
m. Detection Distance (selectable): 8m max. (<24°C)
Selectable Functions via Knob:
a. Selectable daylight luminance level: Sensing luminance level can work both in the daytime and at night when
you select the “sun” position (max) via knob. It can work in the environment that the luminance is less than 3LUX
when it is adjusted to the “3” position (min). As for the adjustment pattern, please refer to the testing pattern.
b. Time-Delay is added continually: When sensor receives the second induction signal after the first induction, it
will perform the time delay period again according to the 2nd induction.
c. Selective time delay period length: It can be set according to the consumer’s desire. The minimum delay period
is 10sec±3sec. The maximum delay period is 15min±3min.
Installation Guide and product diagram
INSTALLATION ADVICE:
As the detector responds to changes of temperature, please avoid the following situations:
a. Avoid directing the detector towards objects with highly reflective surfaces, such as mirrors etc.
b. Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, light etc.
c. Avoid directing the detector towards objects that may move in the wind, such as curtains, tall plants etc.
Step 1
Step 2
Step 3
Good Sensitivity
Poor Sensitivity
Sensitivity
11080850 MS-SV-INF-CR-A-360-230V-IP20 UI LEDV v3.indd 2