background image

www.prolight.co.uk

VersiLED 4 DMX Controller

  

User Manual

4

Initial setup:

Connect the supplied mains power adaptor to the DC power input on the controller and then to a  
suitable mains voltage supply (100-240VAC~50/60Hz).
The controller can be used to control 3 or 4 colour LED products each with or without a dimmer channel.  
The controller is based around LTP (Last Takes Precedence) across its control surface, this means the 
last command executed on the controller will override the previous command. Because of this, the  
controller is easy to use for those who carry little knowledge of DMX controllers.

DMX channel assignment:

 

The controller has preset DMX start addresses for each of the four fixtures. Please set your fixture to the 
following DMX addresses.  
Please note: If two or more fixtures are set to the same DMX address they will receive the same  
DMX commands.

Master dimmer:

 

The controller also has an additional Master Dimmer function. While holding down the Blackout  
button, use the strobe/dimmer fader to adjust the overall master intensity. This function will operate for 
all fixtures regardless of fixture selection. The master dimmer function will override all outputs including 
sound and auto modes. If you have used the master dimmer to dim your fixture(s) to zero you will have 
to dim them back up in order to use manual dimming/colour mixing again.

01) RGBW/D channel faders:

 

The RGBW/D faders are used to create a manual colour mix. First select the fixture groups as required 
from the four fixture groups and then use the faders to adjust the colour and intensity as required.

02) Fixture/group buttons and LED indicators:

 

The fixture/group buttons are used to select or deselect fixtures. Next to each button is an LED  
indicator, this will illuminate when the fixtures are selected.

03) Channel mode selection and LED indicators:

 

The controller can be used to control up to four fixtures/groups from RGB or RGBW, each fixture may 
be set individually to suit the DMX channels of your LED fixtures. Select the desired fixture/group using 
the fixture/group buttons, then select the channel mode. Unselect the fixture/group and then repeat the 
process for each of the four fixture/groups until set. Please note: When using Mode 4 and Mode 6,  
the dimmer channel output value will be 255, this enables you to colour mix and then use the master 
dimmer detailed above.

Operating instructions

Fixture Number Group

DMX Start Address

1

001

2

011

3

021

4

031

Содержание VersiLED 4

Страница 1: ...R DC INPUT DMX OUTPUT 1 Ground 2 Data 3 Data DC 9V 12V 300mA min STROBE G G B B DIMMER STROBE SPEED SPEED MACRO MIX SOUND SENSITIVITY W D W R G B W M1 RGB M2 RGBD M3 RGBW M4 RGBWD M5 DRGB M6 DRGBW 0 100 80 60 40 20 0 100 80 60 40 20 0 100 80 60 40 20 30 SEC 0 1 SEC 1 8 7 6 5 4 3 2 VersiLED 4 www prolight co uk 1 2 3 VersiLED 4 ON I O OFF M1 M4 M2 M5 M3 M6 ...

Страница 2: ...Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the powe...

Страница 3: ...x 202 x 110mm Weight 0 8kg Order code LEDJ321 0 100 80 60 40 20 R R 1 10 11 20 21 30 31 40 1 2 3 4 AUTO CHANNEL MODE SOUND RUN MODE BLACKOUT POWER DC INPUT DMX OUTPUT 1 Ground 2 Data 3 Data DC 9V 12V 300mA min STROBE G G B B DIMMER STROBE SPEED SPEED MACRO MIX SOUND SENSITIVITY W D W R G B W M1 RGB M2 RGBD M3 RGBW M4 RGBWD M5 DRGB M6 DRGBW 0 100 80 60 40 20 0 100 80 60 40 20 0 100 80 60 40 20 30 S...

Страница 4: ... The master dimmer function will override all outputs including sound and auto modes If you have used the master dimmer to dim your fixture s to zero you will have to dim them back up in order to use manual dimming colour mixing again 01 RGBW D channel faders The RGBW D faders are used to create a manual colour mix First select the fixture groups as required from the four fixture groups and then u...

Страница 5: ... fixture group While holding the button the strobe speed can be adjusted using the strobe speed sound sensitivity dimmer fader The strobe speed is adjustable 1Hz 20Hz Please note If the master dimmer function has been set to zero then the strobe will not operate Please set the master dimmer back up for the strobe to function again 07 RGBW colour mix The RGBW colour mix fader can be used for rapid ...

Страница 6: ...11 3 Pin DMX output DMX output connection 3 pin XLR output socket Pin 1 Ground Pin 2 data ve Pin 3 data ve 12 DC power input centre ve Centre positive type connection 9 12VDC 300mA minimum regulated type 13 Power on off switch Use this switch to power the controller on off Macro Channel Value Description N A 000 007 Blackout 1 008 038 Red Green Fade 2 039 069 Red Blue Fade 3 070 100 Green Blue Fad...

Страница 7: ...king DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX add...

Страница 8: ...L89 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always...

Страница 9: ...t possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environment...

Страница 10: ...www prolight co uk VersiLED 4 DMX Controller User Manual 10 ...

Страница 11: ...www prolight co uk VersiLED 4 DMX Controller User Manual 11 ...

Страница 12: ...www prolight co uk VersiLED 4 DMX Controller User Manual 12 ...

Отзывы: