background image

 STAGE WASH U.V.  

 

 

      

 

                                               DMX SET UP

DMX-512: 

• DMX (Digital Multiplex) is a universal protocol used as a form of communication between 

  intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the 

  controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the 

  DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only   

  have a data “out” terminal).

DMX Linking: 

• DMX is a language allowing all makes and models of different manufactures to be linked together   

  and operate from a single controller, as long as all fixtures and the controller are DMX compliant.   

  To ensure proper DMX data transmission, when using several DMX fixtures try to use the 

  shortest cable path possible. The order in which fixtures are connected in a DMX line does not   

  influence the DMX addressing. For example; a fixture assigned to a DMX address of 1 may be  

  placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a   

  fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to 

  address 1 to that unit, no matter where it is located in the DMX chain.

DATA Cable (DMX cable) requirements (for DMX operation):

• The Stage Wash U.V. can be controlled via DMX-512 protocol.  The DMX address is set on the  

  back of the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for 

  data input/output (figure 1). 

 

Figure 1

Also remember that DMX cable must be daisy chained and cannot be split.

 

Further DMX cables can be purchased 

from all good sound and lighting suppliers 

or Prolight dealers.

Please quote:

 

CABL10 – 2M

 

CABL11 – 5M

 

CABL12 – 10M

Содержание Stage Wash 18

Страница 1: ...www prolight co uk STAGE WASH U V 18 order code LEDJ105 USER MANUAL ...

Страница 2: ... CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written...

Страница 3: ...le periodically If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reac...

Страница 4: ...LEDs Sound control via internal microphone Master Slave functions Sound activated 3 pin XLR in out sockets IEC power in out sockets Rugged compact housing Consumption 21W Beam 25 degrees Long life LEDs OPTIONS DMX Channel Summary CHANNEL CH1 CH2 VALUE 000 250 250 255 000 255 FUNCTION DIMMING 100 SOUND ACTIVE SPEED ADJUSTMENT FROM SLOW TO FAST ...

Страница 5: ...w Setup Operating Instructions The Stage Wash U V is a DMX 512 controllable unit made up of high efficiency and super bright Ultra Violet LEDs The Stage Wash U V will operate in stand alone Master Slave sound activated or via DMX 512 control ...

Страница 6: ...tion The Stage Wash U V has a built in microphone which enables it to operate in Sound to Light mode Set dip switch 9 to ON to activate Sound Mode Daisy Chain Connection 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture which will have a female 3 pin connector to the input ...

Страница 7: ...e Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show In this mode you will be able to control each individual trait of the fixture and each fixture independently The Stage Wash U V uses 2 channels of control Enable the DMX control by setting dip switch No 10 to the ON position Use dip switches 1 9 to address each fixt...

Страница 8: ...r By subtracting the largest switch value possible from the selected start address until zero is achieved on on EXAMPLE STARTING ADDRESS Address 10 Pin NO 4 8 Pin NO 2 2 Total 10 Address 24 Pin NO 5 16 Pin NO 4 8 Total 24 DMX address using simple maths 233 128 105 Turn on dip No 8 105 64 41 Turn on dip No 7 41 32 9 Turn on dip No 6 9 8 1 Turn on dip No 4 1 1 0 Turn on dip No 1 You will most likely...

Страница 9: ... shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter whe...

Страница 10: ...a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The chart below details the correct cable conv...

Страница 11: ...STAGE WASH U V Dip Switch Reference Chart DMX Dip Switch Quick Reference Chart Dip Switch Position ...

Страница 12: ...nsions Length 260mm Width 145mm Height 132mm Weight 2 6kgs Power AC input 240V 50hz Fuse Main 20mm Glass 0 5A Fast Blow Control Programming Data input Locking 3 pin XLR male socket Data output Locking 3 pin XLR female socket Protocols DMX 512 USITT DMX channels 2 ...

Отзывы: