background image

 STAGE WASH U.V.  

 

 

 

                                                                  SAFETY

IMPORTANT:

           

The manufacturer will not accept liability for any resulting damages caused 

by the non-observance of this manual or any unauthorised modification to the

equipment.

 

• Never let the power-cable come into contact with other cables. Handle the power-cable 

 

  and all mains voltage connections with particular caution!

 

• Never remove warning or informative labels from the equipment.

 

• Do not open the equipment and do not modify the equipment.

 

• Do not connect this equipment to a dimmer-pack.

 

• Do not switch the equipment on and off in short intervals, as this will reduce the 

 

  system’s life.

 

• Only use the equipment indoors.

 

• Do not expose to flammable sources, liquids or gases.

 

• Always disconnect the power from the mains when equipment is not in use or before 

 

  cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the 

 

  power-cable.

 

• Make sure that the available voltage is between 220v/240v.

 

• Make sure that the power-cable is never crimped or damaged. Check the equipment and 

 

  the power-cable periodically.

 

• If the equipment is dropped or damaged, disconnect the mains power supply immediately. 

 

  Have a qualified engineer inspect the equipment before operating again.

 

• If the equipment has been exposed to drastic temperature fluctuation (e.g. after 

 

  transportation), do not switch it on immediately. The arising condensation might damage 

 

  the equipment. Leave the equipment switched off until it has reached room temperature.

 

• If your product fails to function correctly, discontinue use immediately. Pack the unit 

 

  securely (preferably in the original packing material), and return it to your Prolight dealer 

 

  for service.

 

• Only use fuses of same type and rating.

 

• Repairs, servicing and power connection must only be carried out by a qualified 

 

  technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS.

 

• WARRANTY; One year from date of purchase.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual,

the product may suffer damage and the warranty becomes void.

Incorrect operation may lead to danger e.g.: short-circuit, burns, electric shocks, 

lamp failure etc.

Do not endanger your own safety and the safety of others!

Incorrect installation or use can cause serious damage to people and property.

Содержание Stage Wash 18

Страница 1: ...www prolight co uk STAGE WASH U V 18 order code LEDJ105 USER MANUAL ...

Страница 2: ... CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written...

Страница 3: ...le periodically If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reac...

Страница 4: ...LEDs Sound control via internal microphone Master Slave functions Sound activated 3 pin XLR in out sockets IEC power in out sockets Rugged compact housing Consumption 21W Beam 25 degrees Long life LEDs OPTIONS DMX Channel Summary CHANNEL CH1 CH2 VALUE 000 250 250 255 000 255 FUNCTION DIMMING 100 SOUND ACTIVE SPEED ADJUSTMENT FROM SLOW TO FAST ...

Страница 5: ...w Setup Operating Instructions The Stage Wash U V is a DMX 512 controllable unit made up of high efficiency and super bright Ultra Violet LEDs The Stage Wash U V will operate in stand alone Master Slave sound activated or via DMX 512 control ...

Страница 6: ...tion The Stage Wash U V has a built in microphone which enables it to operate in Sound to Light mode Set dip switch 9 to ON to activate Sound Mode Daisy Chain Connection 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture which will have a female 3 pin connector to the input ...

Страница 7: ...e Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show In this mode you will be able to control each individual trait of the fixture and each fixture independently The Stage Wash U V uses 2 channels of control Enable the DMX control by setting dip switch No 10 to the ON position Use dip switches 1 9 to address each fixt...

Страница 8: ...r By subtracting the largest switch value possible from the selected start address until zero is achieved on on EXAMPLE STARTING ADDRESS Address 10 Pin NO 4 8 Pin NO 2 2 Total 10 Address 24 Pin NO 5 16 Pin NO 4 8 Total 24 DMX address using simple maths 233 128 105 Turn on dip No 8 105 64 41 Turn on dip No 7 41 32 9 Turn on dip No 6 9 8 1 Turn on dip No 4 1 1 0 Turn on dip No 1 You will most likely...

Страница 9: ... shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter whe...

Страница 10: ...a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The chart below details the correct cable conv...

Страница 11: ...STAGE WASH U V Dip Switch Reference Chart DMX Dip Switch Quick Reference Chart Dip Switch Position ...

Страница 12: ...nsions Length 260mm Width 145mm Height 132mm Weight 2 6kgs Power AC input 240V 50hz Fuse Main 20mm Glass 0 5A Fast Blow Control Programming Data input Locking 3 pin XLR male socket Data output Locking 3 pin XLR female socket Protocols DMX 512 USITT DMX channels 2 ...