background image

www.prolight.co.uk

Stage Par CZ 100

  

User Manual

10

Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” 
from 1- 512. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was 
addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 
and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the 
chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent 
fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. 
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”  
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together  
and operate from a single controller, as long as all fixtures and the controller are DMX compliant.  
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest  
cable path possible. The order in which fixtures are connected in a DMX line does not influence the  
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in  
a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a  
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,  
no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. 
Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output,  
see image below.

Also remember that DMX cable must be daisy chained and cannot be split.

DMX setup

Further DMX cables can be 

purchased from all good sound 

and lighting suppliers or  

Pro Light Concepts dealers.
Please quote:

CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

Содержание Stage Par CZ 100

Страница 1: ...Order codes LEDJ190 3000K Black Housing LEDJ190P 3000K Polished Housing LEDJ191 5700K Black Housing LEDJ191P 5700K Polished Housing Stage Par CZ 100 User Manual ...

Страница 2: ...in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 100 240V AC 50 60...

Страница 3: ...DMX and powerCON input output allow for easy connections adding to the host of professional features on these fixtures The traditional par can style housing is available in black or polished aluminium and a gel frame holder is supplied enabling diffusion filters to be fitted 3000K Version 5700K Version Features 1 x 100W warm white LED 3000K Manually adjustable beam angle 15 32 44 280 Lux 2m CRI 80...

Страница 4: ...f the par can The latch can then be moved forwards or backwards smoothly allowing the operator to select the beam angle required between 15 and 32 using the markers provided as a guide Release the spring loaded latch once the beam angle has been selected to prevent any further movement 405mm 302mm 237mm 444mm 419mm Product overview technical specifications ...

Страница 5: ...0 0 1 5 1 2 A d d r DMX address setting b L N d L A S t d N S t No DMX signal C U r V Dimming curves L I N S q U I S q U S C U r O N O F F L E d LED backlight H A L O L E d P r o F LED Halogen profiles d I S P d S I p d I S P Display invert Operating instructions 1 C H 2 C H 3 C H C H N d Channel modes ...

Страница 6: ...ual 6 MENU F H r s Fixture hours t t E N p Fixture temperature A U t O t E S t Auto test U U E r Software version Operating instructions N O y E S F A C t Reset factory settings U H I t S t r O N A N U U 0 0 0 U 2 5 5 Manual mode S 0 0 0 S 2 5 5 ...

Страница 7: ... Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button DMX channel mode To access the DMX channel mode press the MENU button and use the UP and DOWN buttons on the rear of the unit to show CHNd on the LED display Now press the ENTER button and use the UP and DOWN buttons to choose one of the 1 2 or 3 DMX channel modes Press the ENTER button to ...

Страница 8: ...ons to choose between HALO Halogen or LEd LED Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button LED backlight To access the LED backlight setting press the MENU button and use the UP and DOWN buttons on the rear of the unit to show LEd on the LED display Now press the ENTER button and use the UP and DOWN buttons to choose between ON or OfF ...

Страница 9: ... DOWN buttons on the rear of the unit to show FHrS on the LED display Now press the ENTER button The unit will now display the fixtures usage time hours To exit out of any of the above options press the MENU button Reset factory settings To reset factory settings press the MENU button and use the UP and DOWN buttons on the rear of the unit to show FACt on the LED display Now press the ENTER button...

Страница 10: ... a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For...

Страница 11: ...9 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference it is always a...

Страница 12: ...possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmental...

Отзывы: