background image

www.prolight.co.uk

Mood Bar

  

User Manual

10

Notice:

Be sure to follow the diagrams below when making your own cables. Do not connect the cables  
shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs  
outer casing. Grounding the shield could cause a short circuit and erratic behaviour.

Special note: 

Line termination:

When longer runs of cable are used,  
you may need to use a terminator on  
the last unit to avoid erratic behaviour.

Using a cable terminator will decrease  
the possibilities of erratic behaviour. 
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)

5-pin XLR DMX connectors:

Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR fixtures 
may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 
3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.

Termination reduces signal transmission 

problems and interference. It is always 

advisable to connect a DMX terminal, 

(resistance 120 Ohm 1/4 W) between pin 2 

(DMX-) and pin 3 (DMX+) of the last fixture.

5-pin XLR (female)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

Pin 4: N/C

Pin 5: N/C

3-pin XLR (female)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

3-pin XLR (male)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

5-pin XLR (male)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

Pin 4: N/C

Pin 5: N/C

DMX setup

Содержание Mood Bar

Страница 1: ...Order code LEDJ459 Mood Bar User Manual ...

Страница 2: ...hort intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 100 240V AC 50 60Hz M...

Страница 3: ...ar away from any flammable materials and or liquids The fixture must be fixed at least 50cm from surrounding walls The device should be installed out of reach of people and outside areas where persons may walk by or be seated Before rigging make sure that the installation area can hold a minimum point load of 10 times the device s weight Always use a certified safety cable that can hold 12 times t...

Страница 4: ... effects available from this compact unit Several different installation options and brackets are included along with a flip out stand for fast set up if being used by mobile entertainers Mood Bar 230mm 371mm 1605mm 106mm 112 tri colour SMD 5050 LEDs RGB Viewing angle 120 DMX channels 7 or 25 selectable Auto sound active and master slave modes 0 100 dimming and variable strobe Brackets allow for m...

Страница 5: ...Fuse F1A 250V 09 Floor standing bracket 10 Mounting brackets In the box 1 x fixture 1 x PowerCON cable 1 x user manual POWER INPUT 100 240V 50 60Hz POWER OUTPUT 100 240V 50 60Hz 3 PIN DMX OUTPUT 3 PIN DMX INPUT FUSE F1A 250V MENU UP DOWN ENTER www prolight co uk MOOD BAR 01 02 03 06 04 08 07 05 09 10 10 MENU UP DOWN ENTER www prolight co uk MOOD BAR MENU UP DOWN ENTER www prolight co uk MOOD BAR ...

Страница 6: ...MX address settings C H 0 7 C H 2 5 N o d E DMX channel settings S P 0 1 S p 9 9 A u t o Auto mode S U 0 1 S U 0 8 S o U n Sound mode S N 0 0 S N 9 9 S e N S Sound sensitivity setting C O 0 0 C O 0 6 C o L o Static colour mode r g b r 0 0 0 r 2 5 5 g 0 0 0 g 2 5 5 Colour mix mode b 0 0 0 b 2 5 5 ...

Страница 7: ...und mode 3 222 228 Sound mode 4 229 235 Sound mode 5 236 240 Sound mode 6 241 247 Sound mode 7 248 255 Sound mode 8 7 000 255 Auto speed adjustment slow fast 7 channel mode Channel Value Function 1 000 255 Master dimmer 0 100 2 000 255 Strobe slow fast 3 000 255 Red segment 1 dimmer 0 100 4 000 255 Green segment 1 dimmer 0 100 5 000 255 Blue segment 1 dimmer 0 100 6 000 255 Red segment 2 dimmer 0 ...

Страница 8: ...eNs on the LED display Press the ENTER button and then use the UP and DOWN buttons to select any value from SN00 SN99 Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button Static colour mode To access the Static colour mode press the MENU button and use the UP and DOWN buttons on the rear of the unit to show CoLo on the LED display Press the EN...

Страница 9: ... is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing ...

Страница 10: ...pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always advis...

Страница 11: ...le harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally saf...

Страница 12: ...www prolight co uk Mood Bar User Manual 12 ...