background image

www.prolight.co.uk

TPix Panel

  

User Manual

16

Содержание LEDJ472

Страница 1: ...Order code LEDJ472 TPix Panel User Manual ...

Страница 2: ...short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 100 240V AC 50 60Hz ...

Страница 3: ...a wide 120 viewing angle and feature a milky frost effect front screen A clear front screen is also included to further expand the versatility of this series TPix Panel 300mm 117mm 60mm 300mm 144 tri colour SMD 5050 LEDs RGB Viewing angle 120 Illuminance 3290 Nits clear front screen Illuminance 2900 Nits frosted front screen Refresh rate 400Hz Pixels 12 x 12 Pixel pitch 25mm DMX channels 8 Art Net...

Страница 4: ... 13 Fuse T3 15A 250V 14 Hanging bracket 15 Panel to panel alignment brackets 16 Safety eye In the box 1 x fixture 1 x clear front screen 1 x frosted front screen 1 x PowerCON cable 1 x user manual TPix Panel SIGNAL MENU ENTER UP DOWN POWER INPUT 100 240V 50 60Hz FUSE T3 15A 250V POWER OUTPUT 100 240V 50 60Hz POWER CONSUMPTION 55W RJ45 INPUT Artnet Klingnet RJ45 OUTPUT Artnet Klingnet 5 PIN DMX INP...

Страница 5: ...Mix Auto Mode Program 1 Auto Mode 8CH DMX address setting 432CH DMX address setting DMX Address 001 DMX Address 080 DMX Address 504 DMX Address 001 DMX Address DMX channel setting DMX CH Mode DMX CH Mode 8CH DMX CH Mode 432CH Slave mode setting Slave Mode Slave Mode YES NO Slave Mode YES NO Network Settings Network settings IP Address 002 000 000 002 Net SubNet Unive 00 00 00 Subnet Mask 255 000 0...

Страница 6: ...nfirm the setting To exit out of any of the above options press the MENU button IMPORTANT PLEASE NOTE The LCD display for this fixture has a timer that turns the display back light off after 20 seconds of inactivity To illuminate the display again press one of the 4 buttons Channel Value Function 1 000 255 Master dimmer 0 100 2 000 255 Strobe slow fast 3 000 255 Red dimmer 0 100 4 000 255 Green di...

Страница 7: ...nd use the UP and DOWN buttons to select between Program 1 Program 29 or Program Mix Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button Software version To access the fixtures software version press the MENU button and use the UP and DOWN buttons on the rear of the unit to show Software Version on the LCD display Now press the ENTER button a...

Страница 8: ...unit to show Network Settings on the LCD display Now press the ENTER button and use the UP and DOWN buttons to select Net SubNet Universe Press the ENTER button and use the UP and DOWN buttons to select the part of the Net SubNet Universe you would like to change indicated by a Press the ENTER button and use the UP and DOWN buttons to adjust the selected part of the Net SubNet Universe you have ch...

Страница 9: ...Set the Subnet mask to 255 0 0 0 on both the TPix Panel and the software controller Make sure that all fixtures in the network have a unique IP address Please note If you want to connect more than one fixture operating in 432 channel mode is advised Follow the example below Example TPix Panel 432 channel mode 01 Make sure that each connected TPix Panel has a unique IP address 02 Make sure the Subn...

Страница 10: ...le CAT 5 CAT 5E CAT 6 and connect it to an RJ45 connector as shown below Ethernet Patch Cable Colour Standard EIA TIA T568A RJ45 Pin Green White Tracer 1 Green 2 Orange White Tracer 3 Blue 4 Blue White Tracer 5 Orange 6 Brown White Tracer 7 Brown 8 Pin RJ45 1 Green White Tracer 2 Green 3 Orange White Tracer 4 Blue 5 Blue White Tracer 6 Orange 7 Brown White Tracer 8 Brown TX TX RX RX PR 3 PR 3 PR 2...

Страница 11: ...X is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing...

Страница 12: ... pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always advi...

Страница 13: ...ble harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally sa...

Страница 14: ...www prolight co uk TPix Panel User Manual 14 ...

Страница 15: ...www prolight co uk TPix Panel User Manual 15 ...

Страница 16: ...www prolight co uk TPix Panel User Manual 16 ...

Отзывы: