background image

 Spectra Batten 12T3 Exterior 

 

                                                                Trouble Shooting

9.

Problem

One or more fixtures 

are completely dead.

Fixtures reset correctly, but 

all are responding erratically  

or not at all to the controller.

Fixtures reset correctly, but 

some are responding 

erratically or not at all 

to the controller.

No power to the fixture.

Check that the power is switched 

on and cables are connected.

Contact your Prolight dealer.

Internal fuse has blown.

The controller is not connected.

The 3-pin XLR out of the 

controller does not match the 

XLR out of the first fixture 

(i.e. signal is reversed).

Poor data quality.

Check the data quality. If much lower 

than 100%, the problem may be a 

bad data link connection, poor quality 

or broken cables, missing termination 

plug or a defective fixture is disturb-

ing the link.

Bad data link connection.

Inspect the connection and 

cables. Correct the connection. 

Repair or replace the 

damaged cables.

Insert a termination plug into the 

output socket of the last fixture.

Data link not terminated with 120 

Ohm termination plug.

Incorrect addressing of the fixtures.

Check that DMX address setting 

is correct.

One of the fixtures is 

defective and disturbs the data 

transmission on the link.

Bypass one fixture at a time until 

normal operation is regained. 

Unplug both connectors and 

connect them together.

Have the fixture serviced by a 

qualified technician.

The 3-pin XLR Out on the fixture 

do not match (pins 2 and 3 

reversed).

Install a phase reversing cable 

between the controller and the 

first fixture in the link.

Install a phase 

reversing cable between the 

fixtures or swap pin 2 and 3 

in the fixture that behaves 

erratically.

Connect the controller.

Probable cause

Solution

Содержание LEDJ259

Страница 1: ...www prolight co uk Order code LEDJ259 User manual SPECTRA BATTEN 12T3 EXTERIOR...

Страница 2: ...l CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any cons...

Страница 3: ...wer cable is never crimped or damaged Check the equipment and the power cable periodically Avoid direct eye exposure to the light source while the product is on If the equipment is dropped or damaged...

Страница 4: ...upply 100 240V 50 60Hz IP rating IP 66 Dimensions 619 x 120 x 140mm Weight 2 6kg Overview Setup Operating Instructions The Spectra Batten 12T3 Exterior is a DMX 512 controllable unit made up of high e...

Страница 5: ...ect the desired flash value and adjust by using the UP and DOWN buttons Speed values S 00 S 99 00 slow 99 fast Flash values F 00 F 99 00 slow 99 fast In P 01 you can set a specific static colour When...

Страница 6: ...the 1 3 3 4 or 5 channel options dP 1 1 channel mode dP 2 3 channel mode RGB dP 3 3 channel mode Function dP 4 4 channel mode dP 5 5 channel mode To confirm your choice pres the M button For DMX funct...

Страница 7: ...art function 4 channel mode DMX chart Channel 1 2 3 4 Value 0 255 0 255 0 255 0 255 Function Red 0 100 Green 0 100 Blue 0 100 Master dimmer 0 100 5 channel mode DMX chart 6 3 channel mode DMX chart RG...

Страница 8: ...fluence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a...

Страница 9: ...fixture is then supplied with a short 13A to IP66 connector power cord If at any stage the 13A plug is removed please follow the chart below Any changes to the connector types must be verified by a P...

Страница 10: ...a defective fixture is disturb ing the link Bad data link connection Inspect the connection and cables Correct the connection Repair or replace the damaged cables Insert a termination plug into the ou...

Страница 11: ...ing if the problem persists Fixture is too hot The LEDs are damaged The power supply settings do not match the local AC voltage and frequency Allow the fixture to cool down Make sure that all air vent...

Страница 12: ......

Отзывы: