background image

www.prolight.co.uk

Performer 18 HEX

  

User Manual

6

Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” 
from 1- 512. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was 
addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 
and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the 
chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent 
fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. 
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”  
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together  
and operate from a single controller, as long as all fixtures and the controller are DMX compliant.  
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest  
cable path possible. The order in which fixtures are connected in a DMX line does not influence the  
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in  
a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a  
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,  
no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. 
Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output,  
see image below.

Also remember that DMX cable must be daisy chained and cannot be split.

DMX setup

Further DMX cables can be 

purchased from all good sound 

and lighting suppliers or  

Pro Light Concepts dealers.
Please quote:

CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

Содержание LEDJ252B

Страница 1: ...Order code LEDJ252B Performer 18 HEX 18 x 12W 6 in 1 colour LEDs RGBWAUV User Manual ...

Страница 2: ... open the equipment and do not modify the unit Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the p...

Страница 3: ...riable strobe Bracket allows for multiple rigging and floor standing applications 4 push button menu with LED display Captive power connection 3 pin XLR in out sockets Fan cooled Performer 18 HEX Specifications Performer 18 HEX Power consumption 190W Power supply 100 240V 50 60Hz Fuse F2A 250V Dimensions 290 x 270 x 255mm Weight 2 6kg Order code LEDJ252B 0m 1m 2m 3m 4m 5m 40 Lux 29625 6920 3010 40...

Страница 4: ... change mode press MENU until the display shows CC on the LED display Press ENTER to confirm the setting Use the UP and DOWN buttons to ajust the speed between CC00 CC99 Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button Colour fade mode To access colour fade mode press MENU until the display shows CP on the LED display Press ENTER to confir...

Страница 5: ...e rear of the master unit to select your desired program sound active auto static colour or colour fade To set the other units in slave mode press the MENU button on the rear of the unit to show d001 on the LED display and press the ENTER button to confirm the setting The units will now run in sequence with the master unit To exit out of any of the above options press the MENU button Please ensure...

Страница 6: ... a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For...

Страница 7: ... pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interferance it is always advi...

Страница 8: ...ossible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentall...

Отзывы: