Built-in programs:

To access the built-in programs, press the 

“MENU”

 button on the rear of the unit to show  

“1.STATIC”

 on the LCD display. Press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to 

select one of the 4 built-in programs (static colour, colour change, 4 colour change or colour fade).

1.STATIC

 - Press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to select between  

“00” - “99”

 for R (Red), G (Green), B (Blue), W (White) and F (Flash).  

Press the 

“ENTER”

 button to confirm the setting. 

(00 = LED off/strobe off, 99 = LED at full brightness/strobe fast)

For 

2.CHANGE

3.CHANG4 

and 

4.FADE 

programs press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to set the speed from 

“00” - “99”

. Press the 

“ENTER”

 button again and use the 

“UP”

 

and 

“DOWN”

 buttons to set the strobe speed from 

“00” - “99”

Press the 

“ENTER”

 button to confirm the setting.

 

(00 = speed slow, 99 = speed fast).

To exit out of any of the above options, press the 

“MENU”

 button. 

Sound sensitivity:

To adjust the sound sensitivity, press the 

“MENU”

 button on the rear of the unit to show 

“SOUND 

SENS”

 on the LCD display. Press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to set the 

sensitivity from 

“00” - “31”

. Press the 

“ENTER”

 button to confirm the setting.

 

(00 = low sensitivity, 31 = high sensitivity). 

To exit out of any of the above options, press the 

“MENU”

 button. 

IR remote on/off:

To set the IR remote on/off, press the 

“MENU”

 button on the rear of the unit to show 

“IR. REMOTE”

 on 

the LCD display. Press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to select 

“ON” 

or

 

“OFF”

. Press the 

“ENTER”

 button to confirm the setting.

To exit out of any of the above options, press the 

“MENU”

 button.

Dimmer response:

To set the dimmer response, press the 

“MENU”

 button on the rear of the unit to show 

“DIMMER”

 on the 

LCD display. Press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to select 

“RESP_01” 

or

 

“RESP_02”

. Press the 

“ENTER”

 button to confirm the setting.

To exit out of any of the above options, press the 

“MENU”

 button.

Manual dimming mode:

To access the manual dimming mode, press the 

“MENU”

 button on the rear of the unit to show  

“Manual”

 on the LCD display. The unit is now in manual dimming mode. Press the 

“ENTER”

 button  

and use the 

“UP”

 and 

“DOWN”

 buttons to set the brightness from 

“00” - “99”

. Press the 

“ENTER”

 button  

again and use the 

“UP”

 and 

“DOWN”

 buttons to set the strobe speed from 

“00” - “99”

Press the 

“ENTER”

 button to confirm the setting.

 

(00 = LED off/strobe off, 99 = LED at full brightness/strobe fast)

To exit out of any of the above options, press the 

“MENU”

 button. 

Operating instructions

Содержание DP36042

Страница 1: ...Order codes LEDJ234 Black Housing LEDJ234A White Housing Event Spot RGBW MKII User Manual...

Страница 2: ...in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment i...

Страница 3: ...ays for highlighting and pinspotting it can also be used to create mood lighting on a restaurant table or to spotlight displays in store On board features include manual colour selection colour change...

Страница 4: ...trailing socket 05 3 Pin DMX output trailing socket 06 PowerCON input 07 PowerCON output 08 Hanging bracket 09 Hanging bracket adjustable knob In the box 1 x fixture 1 x 10 frost lens 1 x 45 frost le...

Страница 5: ...lour change mode Colour fade mode Static colour mode 1 STATIC R 00 G 00 1 STATIC B 00 W 00 1 STATIC F 00 1 STATIC R 99 G 99 1 STATIC B 99 W 99 1 STATIC F 99 1 STATIC 2 CHANGE SP 00 F 00 2 CHANGE SP 99...

Страница 6: ...een fine adjustment Blue fine adjustment White fine adjustment Calibration password unlock Password 050 Password 000 Password 255 Password Red 000 Red 255 Red Green 000 Green 255 Green Blue 000 Blue 2...

Страница 7: ...MENU button on the rear of the master unit to select manual mode To set the other units in slave mode press the MENU button on the rear of the unit to show SLAVE MODE on the LCD display Press the ENT...

Страница 8: ...sitivity from 00 31 Press the ENTER button to confirm the setting 00 low sensitivity 31 high sensitivity To exit out of any of the above options press the MENU button IR remote on off To set the IR re...

Страница 9: ...Ds 09 Sets the LEDs colour then use the and buttons to change the brightness 1 2 3 4 5 6 0 _ 7 8 9 AW D FL SL SP S S PR SA R G B BLACKOUT DIMMING FLASH SLAVE SPEED SET ADDR SELECT PROG SOUND ACTIVE AM...

Страница 10: ...ng all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data tran...

Страница 11: ...cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin...

Страница 12: ...ossible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material...

Отзывы: