LEDCONN LUXFLEX Premium Скачать руководство пользователя страница 4

 4

301 Thor Place, Brea, CA 92821 | 

tel

 (714) 256-2111 | 

fax

 (714) 256-2118 | [email protected]

www.ledconn.com 

Details are subject to change without notice. © 2019 LEDCONN CORP. All Rights Reserved.

IG.20.01.R0

I N S T A L L A T I O N   G U I D E

SCAN FOR  
DIGITAL VERSION

POWER & WIRING

Controls, dimmers, split connectors, extension cords, power supplies, and accessories are available  
for purchase. 

Before wiring to power supply, always turn off electricity at the fuse or circuit breaker box.

ELECTRICAL POWER CONSIDERATIONS 

• Use the supplied Class 2 power supply to power the LED flexible sheet. The warranty will be forfeited if a power supply not approved by 
LEDCONN is used.  
• LUXFLEX sheets are offered with UL & cUL Listed & Recognized Class 2 power supplies. Please check the input voltage for your flexible 
sheet and use the power supply that matches the indicated voltage.  
• The total power consumption of the lighting fixture must be lower than the rated output power of the power supply and dimming controls.  
• Unless otherwise specified, use only Class 2 power supplies rated 24V or less. LUXFLEX is not suited for power supplies that do not comply 
with Class 2 or are greater than 24VDC. 
• To maintain Class 2 power compliance, do not exceed more than a 96W load. 
• Using a power adapter is essential. Never apply direct AC power. Doing so will instantly burn the LEDs, permanently damage the product, 
and void the warranty.  
• Ensure enough spacing between pieces of assembled LUXFLEX products to avoid conductors shorting against each other. 
• Jumpers & hardwire-to-Molex connections are provided with standard 20AWG wires.
• Please refer to pages 6-7 for further instructions on tiling multiple sheets & power consolidation.

DRIVERS & POWER SUPPLIES 

• Please refer to LED driver manufacturer's instructions for appropriate dimmer, connection instructions, and usage recommendations. 
• Electrical drivers may be remotely mounted. Contact the LEDCONN Engineering team for help if needed. 
• LEDCONN will recommend drivers that match the wattage and voltage requirements of LUXFLEX. 

B

120Vac

HOT

NEUTRAL

Dark Blue

Brown

Electronic LED Driver

Molex

®

 Connector

LUXFLEX™ LED Flexible Sheet

DC Barrel Jack

24VDC Adapter

DC DRIVER TO MOLEX CONNECTOR

HARDWIRE DRIVER-TO-MOLEX CONNECTOR

DIMMING INSTRUCTIONS

1) Connect the power adapter and flexible sheet to the dimmer per 
dimmer instructions.
2) Using the dimmer, adjust the light to the desired brightness level.
3) You may use one dimmer for a multi-sheet installation as long as 
the total power consumption is lower than dimmer rated power.
4) For optimal performance and brightness, use LEDCONN 
recommended compatible dimmers. Consult with LEDCONN 
engineers for compatibility concerns.

COMPATIBLE DIMMER TYPES

IN-LINE DIMMER

DIMMER WITH

REMOTE CONTROL

MAGNETIC (MLV)  

& 0-10V

LUXFLE X

Static White & RGBW

FLEXIBLE SHEET

Содержание LUXFLEX Premium

Страница 1: ...t hot spots Avoid placing heavy objects on LUXFLEX No heat sink is required for installation AIRGAPS 3 4 Recommended airgap between product substrate depending on face material opacity for optimum bac...

Страница 2: ...tly 2 Solvent Wipe To obtain optimum adhesion the bonding surfaces must be cleaned and smooth Most substrates are best prepared by cleaning with a mixture of isopropyl alcohol IPA and water 3 Wipe Dry...

Страница 3: ...ors or a knife CUTTING TIPS 1 Only cut along designated cut lines Do not cut outside of designated cut lines otherwise the electrical circuit will break 2 For LUXFLEX premium standard the smallest pie...

Страница 4: ...er Doing so will instantly burn the LEDs permanently damage the product and void the warranty Ensure enough spacing between pieces of assembled LUXFLEX products to avoid conductors shorting against ea...

Страница 5: ...ers with dip switches require the address to be manually set by the dip switches Using Digital DMX Decoders LEDCONN does not provide factory programmed digital DMX controls however when a DMX decoder...

Страница 6: ...r supplies as short as possible to prevent voltage drop We recommend keeping wire gauges no larger than 12AWG and 40ft long for optimal wire management We recommend heavier wire guages for longer dist...

Страница 7: ...ish to connect 5 LEDs will immediately light up if the wiring is correct 6 Following the wiring diagrams provided by the LEDCONN team connect pieces or sheets to power supplies following the same pola...

Страница 8: ...th the construction and operation of the product and the hazards involved Do not make or alter any open holes in an enclosure of wiring or electrical components during installation Please retain these...

Отзывы: