21
when engaged,remove the right side plastic housing and
check the wire connectors to the switch for any loose or
broken wires.Re-connect or replace and rewire as shown in
the schematic.Next,using a multimeter check the continuity
of the switch(disconnect the power cord first) by putting your
probes on the the two inner most switch terminals and
engaging the switch..If there is no continuity present,the
switch is faulty and should be replaced(part # PRS310) and
rewired as shown in the schematic.The fan system should
now be operational.If not,consult a servicing dealer/tech,the
Ledco service dept or proceed to the next,Advanced,
troubleshooting level.
3)
Advanced.
If,after following the sequential
troubleshooting guidelines,excessive wrinkling persists
(especially with an hour glass shaped dwell line resulting in
center wrinkling),the rubber rolls may be excessively worn,
damaged or faulty and need to be replaced.Please follow
the dis-assembly removal ,replacement and re-assembly
instructions in the advanced level of Section 3 for successful
rubber roll replacement. Lamination should then be smooth
and wrinkle free.
To further troubleshoot and/or repair the fans,you have to
remove the back,bottom motor cover as explained earlier in
SECTION 2,A-3.Visually inspect all wires and connectors for
the 3 fan motors,replace or rewire as needed per schematic.
Next using a multimeter set at Volts AC,follow the black and
white wires that come from the terminal block to the first
white wire cap connection for the fans.Power up the
machine and insert the probes into the first cap connector,
checking for 110 Vac,then the second wire cap connector
checking for the same.If proper voltage is evident through