www.lectrosonics.com
5
UP Button Menu
Hold the UP button while powering up the unit. Then press the AUDIO but-
ton repeatedly to scroll through and select the following settings below. Use
the UP and DOWN arrows to select the available options under each setting.
•
CP (compatibility mode); press the UP and DOWN arrows to select one of
the following:
CP 400 400 Series (Digital Hybrid) mode
CP 3 Mode 3 (contact the factory for details)
CP 200 200 Series mode; receivers UCR200/201/205D/210/211
CP 100 100 Series mode; UCR100 receiver
CP 7 Mode 7 (contact the factory for details)
CP 6 Mode 6 (contact the factory for details)
CP IFb IFB Series mode; IFBR1/1a receivers
•
Pr (RF power output in mW); selections: 25, 50
•
In (Input configuration); press the UP and DOWN arrows to select one of
the following:
In dYn no bias, 0 (300 ohm); for dynamic microphones
In CoS 4v bias, 0 (300 ohm); phase reversed; for Sanken COS11,
Lectrosonics M152 and similar mics
In b6 2v bias, 0 (300 ohm); for Countryman B6 and similar mics
In dPA 4v bias, Lo (4k ohms); use for DPA lavaliere and similar mics
In L In no bias, HI (100k ohms); use for line level input
In otH 4v bias, 0 (300 ohms); same as CoS but audio phase is not
reversed; for various mics
In SEt Press the AUDIO button for manual setup to select the
following parameters, then use the UP and DOWN
arrows for each item to set the values.
bIAS bias voltage on the input; selections 0, 2 or 4
rES input impedance; selections: 0 (300 ohms),
Lo (approx. 4k ohms) or HI (approx. 100k ohms)
AP audio polarity (aka “phase”); selections: P for positive,
n for negative (reversed)
NOTE: When you press AUDIO after setting the polarity (AP), the screen will leave
this submenu and move to the StP item below. To return to this submenu, press
AUDIO repeatedly and scroll through the menu again starting with CP at the top.
In SEn 4v bias, 0 (300 ohms); same as CoS but audio phase is not
reversed; for various mics, same as otH; listed for easy
selection
In 152 4v bias, 0 (300 ohm); same as CoS but audio phase is not
reversed; for various microphones, same as otH; listed for
easy selection
•
StP (frequency tuning step size in kHz) selections: 25 or 100 kHz
Содержание SSM
Страница 8: ......