If your system malfunctions, you should attempt to correct or isolate the trouble before concluding that the equipment 

needs repair.  Make sure you have followed the setup procedure and operating instructions.  Check the interconnect-

ing cables and then go through the 

Troubleshooting section in this manual.

We strongly recommend that you 

do not try to repair the equipment yourself and do not have the local repair shop 

attempt anything other than the simplest repair.  If the repair is more complicated than a broken wire or loose connec-

tion, send the unit to the factory for repair and service.  Don’t attempt to adjust any controls inside the units.  Once 

set at the factory, the various controls and trimmers do not drift with age or vibration and never require readjustment.  

There are no adjustments inside that will make a malfunctioning unit start working.

LECTROSONICS’ Service Department is equipped and staffed to quickly repair your equipment.  In warranty repairs 

are made at no charge in accordance with the terms of the warranty.  Out-of-warranty repairs are charged at a modest 

flat rate plus parts and shipping.  Since it takes almost as much time and effort to determine what is wrong as it does 

to make the repair, there is a charge for an exact quotation.  We will be happy to quote approximate charges by phone 

for out-of-warranty repairs.

Returning Units for Repair

For timely service, please follow the steps below:
A.

  DO NOT return equipment to the factory for repair without first contacting us by email or by phone.  We need 

to know the nature of the problem, the model number and the serial number of the equipment.  We also need a 

phone number where you can be reached 8 A.M. to 4 P.M. (U.S. Mountain Standard Time).

B.

  After receiving your request, we will issue you a return authorization number (R.A.).  This number will help speed 

your repair through our receiving and repair departments.  The return authorization number must be clearly shown 

on the 

outside of the shipping container.

C.  Pack the equipment carefully and ship to us, shipping costs prepaid.  If necessary, we can provide you with the 

proper packing materials.  UPS is usually the best way to ship the units.  Heavy units should be “double-boxed” for 

safe transport.

D.

  We also strongly recommend that you insure the equipment, since we cannot be responsible for loss of or dam

-

age to equipment that you ship.  Of course,  we insure the equipment when we ship it back to you.

Lectrosonics USA:
Mailing address: 

 

Shipping address: 

 

Telephone: 

Lectrosonics, Inc. 

 

Lectrosonics, Inc. 

 

(505) 892-4501

 

PO Box 15900 

 

581 Laser Rd.   

 

(800) 821-1121 Toll-free

 

Rio Rancho, NM 87174 

Rio Rancho, NM  87124  

(505) 892-6243 Fax

 

USA   

 

 

USA

 

 

 

 

Web:  

 

 

E-mail: 

www.lectrosonics.com  

[email protected]

Lectrosonics Canada:
Mailing Address: 

 

Telephone: 

 

 

E-mail: 

49 Spadina Avenue,   

(416) 596-2202  

 

Sales:    [email protected] 

 

Suite 303A   

 

(877) 753-2876 Toll-free  

Service:  [email protected]

 

Toronto, Ontario M5V 2J1 

(877-7LECTRO)

 

 

 

 

 

(416) 596-6648 Fax

Содержание MM400C

Страница 1: ...C Watertight Miniature UHF Belt Pack Transmitter Featuring Digital Hybrid Wireless Technology INSTRUCTION MANUAL Rio Rancho NM USA www lectrosonics com Fill in for your records Serial Number Purchase...

Страница 2: ...MM400C LECTROSONICS INC 2...

Страница 3: ...e for use with modern electret lavaliere microphones Multi color LEDs are provided to make input gain adjustments quick and accurate without having to view the receiver The battery compartment accepts...

Страница 4: ...MM400C LECTROSONICS INC 4...

Страница 5: ...8 Power ON OFF Switch 8 Power LED 8 Mic Jack 9 Audio Level 9 Modulation LEDs 9 Frequency Select Switches 9 Antenna 9 Belt Clip 9 Battery Installation 10 Operating Instructions 11 Selecting the Compati...

Страница 6: ...ng the audio in the transmitter and decoding it in the receiver yet still sending the encoded informa General Technical Description tion via an analog FM wireless link This proprietary algorithm is no...

Страница 7: ...tem uses an ultrasonic tone between 25 and 32 kHz to operate the receiver squelch The pilot tone squelch system keeps the receiver muted until it receives the pilot tone from the matching trans mitter...

Страница 8: ...See Operating Instructions Power Switch Function Selec tion These functions are illustrated in the chart below Power Switch Position Function ON OFF Normal or Applies Power Turns Unit Off Power Mode...

Страница 9: ...and the switch is configured for Audio Mute Mode 10 and 20 LEDs operate normally to indicate audio level Mic Jack 330pF 330pF FB FB 100 2k 2k 30uF 6V Mic Bias To Mic Amp 2k 2 2nF Frequency Select Swit...

Страница 10: ...your receiver manual to determine if this function is available Alkaline batteries provide about 1 75 hours of operation with some warning Lithium batteries can be used to provide over 6 hours of oper...

Страница 11: ...tter off and leave the receiver turned on Scan across the frequency band to find a frequency where little or no RF activity is dis played Set both the transmitter and the receiver to this new frequenc...

Страница 12: ...he O ring and allow moisture to enter the unit 3 Mute the main sound system and rotate the Audio Level Control on the MM400C to maximum counter clockwise Off 4 Set the Power ON OFF switch to the ON po...

Страница 13: ...If the PWR LED glows and the 10 Modulation LED blinks green the Power Switch is in Audio Mute Mode If the LEDs extinguish the Power Switch is in Normal or Power Mode Changing Power Switch Function 1...

Страница 14: ...ething metallic as illustrated in the example use extreme caution not to scratch the finish Breaching the finish may cause corrosion of the metal housing 2 Notice that the Magnet Housing Assembly Slot...

Страница 15: ...ule If this is not pos sible or if you are still having problems capacitors can be installed on the mic wires inside the TA5F connector housing Install the capacitors as follows Use 330 pF capaci tors...

Страница 16: ...lock range is labeled on the ouside housing for each indi vidual transmitter FREQUENCY CAP ANTENNA BLOCK RANGE COLOR WHIP LENGTH 470 470 100 495 600 Black 5 37 19 486 400 511 900 Black 5 16 20 512 000...

Страница 17: ...ty mode mismatched 5 Transmitter audio muted 1 Transmitter gain audio level is far too high Check Modulation LEDs on transmitter and receiver as it is being used See Operating Instructions Attaching a...

Страница 18: ...This device should be installed and operated so that its antenna s are not co located or operating in conjunction with any other antenna or transmitter Emission Designator 180KF3E Specifications subje...

Страница 19: ...of warranty repairs Returning Units for Repair For timely service please follow the steps below A DO NOT return equipment to the factory for repair without first contacting us by email or by phone We...

Страница 20: ...sonics Inc will pay for the cost of returning your equipment to you This warranty applies only to items returned to Lectrosonics Inc or an authorized dealer shipping costs prepaid within one year from...

Отзывы: