Lectranator Systems DIG60 Скачать руководство пользователя страница 9

Section 2b 

– INSTALLATION 

 

 

CLEAN UNION 

SCREEN 

REGULARLY 

 
 
 
 

 

Cell and Manifold Installation 

Your Lectranator System is adaptable for use with the 13 blade ( RC-13) cell. The manifold must be located as the last 
accessory in the 

POOL RETURN LINE 

only. For special plumbing configurations, please contact your representative for 

assistance in locating the manifold. 

Standard Manifold Assembly: 

 

Bypass flow rate should be set at 94.5 L/min. (25 US Gallons/min.

)

Tri sensor 

 
 

 

IG60 = RC13 Cell 

 
 

 

union 

 
 

flow in 

flow out to pool 

 

For other plumbing configurations, please contact your representative for assistance.  

 

Verification of Flow Switch Protection: 

It is important to 

ANNUALLY 

inspect and verify the safe and proper operation of the Tri-sensor’s Flow Switch protection 

device. We recommend following this procedure to verify that the flow switch is working as designed, which is to halt power 
from being sent to the cell in the presence of insufficient flow. A defective Flow Switch could cause serious personal and/or 
equipment damage. Using either a GOLF BALL or small plastic wrap (saran wrap, food wrap or zip lock bag), block off flow 
to the upper portion of the manifold by placing the golf ball in the strainer screen union or by wrapping the strainer screen with 
the plastic wrap and placing it back in the union and tightening. Operating the system on with this blockage should detect a 
FLOW obstruction, indicated on the digital display and activating a red flashing CHECK SYSTEM light. Once this protection 
feature has been verified, remove the plastic wrap or golf ball, replace the strainer screen and resume operation. Turn the 
output dial to OFF and contact the factory if the flow switch protection is not working properly. 

Golf Ball 

Plastic Wrap 

 

 

union 

OR 

Содержание DIG60

Страница 1: ...e gases which can result in FIRE OR EXPLOSION DOMESTIC READ THE LABEL AND THE INSTALLATION AND OPERATION MANUAL BEFORE USING KEEP OUT OF REACH OF CHILDREN Imported to Canada by LECTRANATOR SYSTEMS INC 1034 72 Avenue N E Calgary Alberta T2E8V9 Phone 1 866 517 7584 REGISTRATION NO 27843 PEST CONTROL PRODUCTS ACT LECTRANATOR DIGITAL MODEL DIG60 Chlorine or Bromine Generating One DIG60 unit can treat ...

Страница 2: ... CONTROL PRODUCTS ACT and Lectranator Digital Model DIG60 REGISTRATION NUMBER 27843 PEST CONTROL PRODUCTS ACT This cell must only be used on these models of chlorine or bromine generating device Read the Label and the Installation and Operation Manual of the chlorine or bromine generating device Lectranator Soft Touch Model ST60 or Lectranator Digital Model DIG 60 before using Lectranator Systems ...

Страница 3: ...s Bacteria And Algae In Swimming Pool Waters For Indoor or Outdoor Use RETAIN MANUAL FOR FUTURE REFERENCE C NSF50 IMPORTANT READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING Notice to User This pest control product is to be used only in accordance with the directions on the label It is an offence under the Pest Control Product Act to use this product in a way that is inconsistent with the...

Страница 4: ...TLINE 1 866 517 7584 or 1 403 291 9845 FAX 1 403 291 1023 Visit Us On The Internet www lectranator com Manufactured for Lectranator Systems Inc 1034 72 Avenue N E Calgary Alberta Canada T2E 8V9 Lectranator Digital Model DIG60 by LECTRANATOR SYSTEMS INC Model RC 13 Serial Number Cell Cell Model Number DIG60 Serial Number Control Unit Control Unit Installer Date of Installation ...

Страница 5: ...e with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times Children should not use spas hot tubs or pools without permanent adultsupervision Equipment Related 115 230VAC 50 60 Hz Models fixed wiring 1 A wire connector is provided on your Lectranator Digital Model DIG60 to connect a minimum 8 4 ...

Страница 6: ...nsor Connections Remote ORP Connections 2b Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Display Panel 7 9 3b Pool Water Preparation 10 Salt Requirement Chart Start Up Procedure s 3c Monitoring and Maintenance 11 Water Chemistry Parameters Saturation Index Section 4 SERVICE and MAINTENANCE 4a Control Box and Fuse Locations 12 Tri Sens...

Страница 7: ...e 10 forsalt requirements the tri sensor assembly holes to tighten the screws RATINGS Input Power 115 VAC 3 0 AC amps MaximumOutput Equivalent to 0 88 kg 1 92 lbs of free available chlorine or bromine day 230 VAC 1 5 AC amps RC 13 Cell Power Level 3 8 amps DC 50 60 Hz Cell Life Expectancy A minimum of 15 000 ampere hours Output Power Cell Power 1 5 0 DC amps Agency Approvals NSF ETL us ETL c CE Ce...

Страница 8: ...ion to the LOAD SIDE of your time clock electronic controller switch or relay to work in conjunction with your circulation pump For control of your main circulation pump single or two speed through the Lectranator Digital Model DIG60 s Internal Relay cut and strip the pre wired Line In wires and jump 1 to 3 and 2 to 4 Gr Yel can be discarded Route a new set of Pump AC Line IN wires from the circui...

Страница 9: ...ollowing this procedure to verify that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or equipment damage Using either a GOLF BALL or small plastic wrap saran wrap food wrap or zip lock bag block off flow to the upper portion of the manifold by placing the golf b...

Страница 10: ...til the end of the cycle or when manually discontinued When Boost is activated with External Timer setting programmed the time remaining for the boost cycle is held in memory and will start up in Boost mode until expired With Pump Program or 2 Speed Pump setting programmed the time clock will be over ridden producing sanitizer until the end of the boost cycle The display will indicate the BOOST Mo...

Страница 11: ...ric displays volume in gallons or cubic meters salt additions in lbs or kg Back Main Menu 2 0 2 2 Temperature Units displays the water temperature in Fahrenheit or Celsius Back Main Menu 2 0 2 3 12 24 hour Time displays the current time in 12 hour Time or 24 hour Time units Back Main Menu 2 0 2 4 Set Time of Day sets the time as follows Set Hours Set Minutes 2 5 Pump Program 1 allows you to progra...

Страница 12: ...tion solution 3 8 Replace Cell Only used when replacing cells May be used to zero the amp hour counter Consult Lectranator Systems Inc for details 3 9 Back Main Menu returns to MAIN MENU 4 0 INSTALLER MENU Hold Select for 10 seconds to enter this mode Use UP DOWN ARROW and SELECT to scroll through the sub menu After completing a step it displays the next step 4 1 English Metric displays volume in ...

Страница 13: ...es in the salt Ensure that ANY salt you use contains a minimum purity of 99 Sodium Chloride NaCl NOTE Do not use Rock Salt due to its high levels of impurities TEST YOUR WATER FOR SALT LEVEL FIRST with the provided salt test strips and then use the chart below to determine the amount of salt to add SALT REQUIREMENT CHART KILOS LBS OF SALT NEEDED FOR 3000 PPM RESIDUAL SALT Level Before Addition Poo...

Страница 14: ...cid levels at the same time as your salt level as these tend to deplete at the same rate Regulations may exist regarding the use of cyanuric acid please consult your local authority NOTE For Bromine or indoor pools it is not necessary to add stabilizer SALT RESIDUAL Your Lectranator Digital Model DIG60 works most efficiently with salt levels between 2 8 3 2 gm l 2800 3200 ppm If it falls below 2 8...

Страница 15: ... electrical connections and fuses Fuse Location and Ratings F1 Main AC Power Fuse 6 Amps 250 VAC F2 F3 Control Panel Circuit Board Fuse Cell Fuse 3 Amps 250 VAC 10 Amps 250 VAC TRI SENSOR ASSEMBLY The Tri sensor assembly tests for Flow Salt and Water temperatures A minimum flow rate of 94 5 L min 25 US Gallons min is required to activate the flow switch As the water flow closes the paddle a magnet...

Страница 16: ...be treated with a mixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution in a container high enough to cover the Cell blades You may also use TABEX LectraClean non fuming pre mixed cell cleaner per label directions Remove the Cell cord and immerse the Cell so that the blades are completely covered in the solution for up to 15 minutes An effervescences action indicates the cal...

Страница 17: ...lytic Cell Cell Unions and Cord ordered separately 12 ft 3 6m Cell Cord 952 1 Union O Ring 19013 Nut Half only 2 pcs for 2 in 50 mm S x S Union Thread Half Only for 2 in 50 mm S x S Union Tri Sensor Assembly Cord Ordered Separately DirectionalFlowIndicator View of locking Quick connect heads 12 ft 3 6m Tri Sensor Cord 956 DIG Tri Sensor O Ring 19028 Temperature Sensor Post Salt Sensor Blades Flow ...

Страница 18: ... and corrosion 4 Premature Cell Failure Requires Replacement Cell A Abnormally high Cell usage due to an insufficient A Check the stabilizer level and adjust to recommended levels Stabilizer Cyanuric acid level B ExcessiveScale DebrisintheCell B See Section 2 above C Cell Type selection not matched to the Cell installed C Follow the INSTALLER SETUP instructions see page 8 5 White Flakes in the Wat...

Страница 19: ......

Отзывы: