Section 3a 

– OPERATION 

Key Features – continued 

 

 

 

 

 

Use 

UP/DOWN ARROW 

and 

SELECT 

to scroll through the sub-menu. After completing a step, it displays the next step: 

3.1 

Test

: same as 1.0 above plus cell 

Amp-hrs 

– then returns to Main Menu (3.0) 

3.2-3.4 

Set Time of Day

: same as 2.4 above 

3.5

 

Force Reverse

: allows you to check cell volts and amps in the opposite direction (verifies reversing feature) 

3.6

 

Set Reverse Time 

: allows adjustable self-cleaning reverse rate of 

2

4

or 

16 

hrs; 

Back – Main Menu 

(3.0) 

Cell reversal is set on 4-hrs from the factory for ideal cell life. For conditions such as high calcium levels that can 
cause the cell to scale quicker than the s elf-cleaning cycle can control, change the setting to “2” hours.  
For vinyl liner pools or optimum water chemistry balance according to the Saturation Index, see page 10, changing the 
REVERSING cycle to “8” or “16” hours will extend the life of the cell. 

If the Reverse Time is set to the “16” hours setting, check the cell weekly for the first month to ensure no scale 

develops. If there is scale development, change the setting to “8” hours. 

Note

: changing the Reversing Time to “2” hours will affect the cell life. However, operating with scale 

development on the cell is more damaging to the life of the cell and changing the reversing time is suggested 

3.7

 

Calibrate Salt

: allows you to calibrate the salt display. Contact the factory for calibration solution 

3.8

 

Replace Cell

: Only used when replacing cells. May be used to zero the amp  -hour counter. Consult Lectranator 

Systems Inc. for details 

3.9

 

Back – Main Menu 

(returns to MAIN  MENU) 

 

4.0

 

INSTALLER MENU 

(Hold 

Select 

for 10 seconds to enter this mode) 

Use 

UP/DOWN ARROW 

and 

SELECT 

to scroll through the sub-menu. After completing a step, it displays the next step: 

4.1

 

English

/

Metric

: displays volume in gallons or cubic meters; salt additions as lbs or kg; 

Back –  Main Menu 

(4.0) 

4.2

 

Temperature Units

: displays the water temperature in 

Fahrenheit 

or 

Celsius 

Back - Main Menu 

(4.0) 

4.3

 

12/24-hour Time 

: displays the current time in 

12-hour Time 

or 

24-hour Time 

units; 

Back – Main Menu 

(4.0) 

4.4

 

Set Pool Volume 

: displays the volume of the pool in either 

Gallons 

or 

Cubic Meters 

4.5

 

Set Cell Power

: allows you to set the 

Power Level = 1, 2 or 3. Warning: Operating on “1” reduces cell power 

but extends cell life, “3” increases cell power but reduces cell life. Back – Main Menu 

(4.0) 

4.6

 

Set Pump Config

: allows you to select from 

External Timer

One-Speed Pump 

or 

Two-Speed Pump 

configuration 

4.7- 4.9 

Set Time of Day

: same as 2.4 – 2.6 above 

4.10 

Back – Main Menu 

(returns to MAIN MENU) 

 

Error Messages: 

If the message 

“Sanitizer Off” 

is shown, the system halts sanitizer production. This is shown when the unit is at rest or when 

the salt level is extremely low. 
If the message 

“Warning!” 

is shown, the system will continue to produce sanitizer but at a reduced efficiency. This is 

associated with a warning message to check the system. 

Lectranator Digital 

Model DIG60 

S a n i t i z e r  

100% 

12:00P 

80F 

 

ON 

Check 

System 

Boost 

Menu 

Select 

Pump 

Содержание DIG60

Страница 1: ...e gases which can result in FIRE OR EXPLOSION DOMESTIC READ THE LABEL AND THE INSTALLATION AND OPERATION MANUAL BEFORE USING KEEP OUT OF REACH OF CHILDREN Imported to Canada by LECTRANATOR SYSTEMS INC 1034 72 Avenue N E Calgary Alberta T2E8V9 Phone 1 866 517 7584 REGISTRATION NO 27843 PEST CONTROL PRODUCTS ACT LECTRANATOR DIGITAL MODEL DIG60 Chlorine or Bromine Generating One DIG60 unit can treat ...

Страница 2: ... CONTROL PRODUCTS ACT and Lectranator Digital Model DIG60 REGISTRATION NUMBER 27843 PEST CONTROL PRODUCTS ACT This cell must only be used on these models of chlorine or bromine generating device Read the Label and the Installation and Operation Manual of the chlorine or bromine generating device Lectranator Soft Touch Model ST60 or Lectranator Digital Model DIG 60 before using Lectranator Systems ...

Страница 3: ...s Bacteria And Algae In Swimming Pool Waters For Indoor or Outdoor Use RETAIN MANUAL FOR FUTURE REFERENCE C NSF50 IMPORTANT READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING Notice to User This pest control product is to be used only in accordance with the directions on the label It is an offence under the Pest Control Product Act to use this product in a way that is inconsistent with the...

Страница 4: ...TLINE 1 866 517 7584 or 1 403 291 9845 FAX 1 403 291 1023 Visit Us On The Internet www lectranator com Manufactured for Lectranator Systems Inc 1034 72 Avenue N E Calgary Alberta Canada T2E 8V9 Lectranator Digital Model DIG60 by LECTRANATOR SYSTEMS INC Model RC 13 Serial Number Cell Cell Model Number DIG60 Serial Number Control Unit Control Unit Installer Date of Installation ...

Страница 5: ...e with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times Children should not use spas hot tubs or pools without permanent adultsupervision Equipment Related 115 230VAC 50 60 Hz Models fixed wiring 1 A wire connector is provided on your Lectranator Digital Model DIG60 to connect a minimum 8 4 ...

Страница 6: ...nsor Connections Remote ORP Connections 2b Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Display Panel 7 9 3b Pool Water Preparation 10 Salt Requirement Chart Start Up Procedure s 3c Monitoring and Maintenance 11 Water Chemistry Parameters Saturation Index Section 4 SERVICE and MAINTENANCE 4a Control Box and Fuse Locations 12 Tri Sens...

Страница 7: ...e 10 forsalt requirements the tri sensor assembly holes to tighten the screws RATINGS Input Power 115 VAC 3 0 AC amps MaximumOutput Equivalent to 0 88 kg 1 92 lbs of free available chlorine or bromine day 230 VAC 1 5 AC amps RC 13 Cell Power Level 3 8 amps DC 50 60 Hz Cell Life Expectancy A minimum of 15 000 ampere hours Output Power Cell Power 1 5 0 DC amps Agency Approvals NSF ETL us ETL c CE Ce...

Страница 8: ...ion to the LOAD SIDE of your time clock electronic controller switch or relay to work in conjunction with your circulation pump For control of your main circulation pump single or two speed through the Lectranator Digital Model DIG60 s Internal Relay cut and strip the pre wired Line In wires and jump 1 to 3 and 2 to 4 Gr Yel can be discarded Route a new set of Pump AC Line IN wires from the circui...

Страница 9: ...ollowing this procedure to verify that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or equipment damage Using either a GOLF BALL or small plastic wrap saran wrap food wrap or zip lock bag block off flow to the upper portion of the manifold by placing the golf b...

Страница 10: ...til the end of the cycle or when manually discontinued When Boost is activated with External Timer setting programmed the time remaining for the boost cycle is held in memory and will start up in Boost mode until expired With Pump Program or 2 Speed Pump setting programmed the time clock will be over ridden producing sanitizer until the end of the boost cycle The display will indicate the BOOST Mo...

Страница 11: ...ric displays volume in gallons or cubic meters salt additions in lbs or kg Back Main Menu 2 0 2 2 Temperature Units displays the water temperature in Fahrenheit or Celsius Back Main Menu 2 0 2 3 12 24 hour Time displays the current time in 12 hour Time or 24 hour Time units Back Main Menu 2 0 2 4 Set Time of Day sets the time as follows Set Hours Set Minutes 2 5 Pump Program 1 allows you to progra...

Страница 12: ...tion solution 3 8 Replace Cell Only used when replacing cells May be used to zero the amp hour counter Consult Lectranator Systems Inc for details 3 9 Back Main Menu returns to MAIN MENU 4 0 INSTALLER MENU Hold Select for 10 seconds to enter this mode Use UP DOWN ARROW and SELECT to scroll through the sub menu After completing a step it displays the next step 4 1 English Metric displays volume in ...

Страница 13: ...es in the salt Ensure that ANY salt you use contains a minimum purity of 99 Sodium Chloride NaCl NOTE Do not use Rock Salt due to its high levels of impurities TEST YOUR WATER FOR SALT LEVEL FIRST with the provided salt test strips and then use the chart below to determine the amount of salt to add SALT REQUIREMENT CHART KILOS LBS OF SALT NEEDED FOR 3000 PPM RESIDUAL SALT Level Before Addition Poo...

Страница 14: ...cid levels at the same time as your salt level as these tend to deplete at the same rate Regulations may exist regarding the use of cyanuric acid please consult your local authority NOTE For Bromine or indoor pools it is not necessary to add stabilizer SALT RESIDUAL Your Lectranator Digital Model DIG60 works most efficiently with salt levels between 2 8 3 2 gm l 2800 3200 ppm If it falls below 2 8...

Страница 15: ... electrical connections and fuses Fuse Location and Ratings F1 Main AC Power Fuse 6 Amps 250 VAC F2 F3 Control Panel Circuit Board Fuse Cell Fuse 3 Amps 250 VAC 10 Amps 250 VAC TRI SENSOR ASSEMBLY The Tri sensor assembly tests for Flow Salt and Water temperatures A minimum flow rate of 94 5 L min 25 US Gallons min is required to activate the flow switch As the water flow closes the paddle a magnet...

Страница 16: ...be treated with a mixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution in a container high enough to cover the Cell blades You may also use TABEX LectraClean non fuming pre mixed cell cleaner per label directions Remove the Cell cord and immerse the Cell so that the blades are completely covered in the solution for up to 15 minutes An effervescences action indicates the cal...

Страница 17: ...lytic Cell Cell Unions and Cord ordered separately 12 ft 3 6m Cell Cord 952 1 Union O Ring 19013 Nut Half only 2 pcs for 2 in 50 mm S x S Union Thread Half Only for 2 in 50 mm S x S Union Tri Sensor Assembly Cord Ordered Separately DirectionalFlowIndicator View of locking Quick connect heads 12 ft 3 6m Tri Sensor Cord 956 DIG Tri Sensor O Ring 19028 Temperature Sensor Post Salt Sensor Blades Flow ...

Страница 18: ... and corrosion 4 Premature Cell Failure Requires Replacement Cell A Abnormally high Cell usage due to an insufficient A Check the stabilizer level and adjust to recommended levels Stabilizer Cyanuric acid level B ExcessiveScale DebrisintheCell B See Section 2 above C Cell Type selection not matched to the Cell installed C Follow the INSTALLER SETUP instructions see page 8 5 White Flakes in the Wat...

Страница 19: ......

Отзывы: