![LeCroy USB Protocol Suite Advisor T3 Скачать руководство пользователя страница 257](http://html1.mh-extra.com/html/lecroy/usb-protocol-suite-advisor-t3/usb-protocol-suite-advisor-t3_user-manual_1866295257.webp)
USB Protocol Suite
User Manual
Chapter 10: Recording Options
LeCroy Corporation
243
Analyzer mode (but not Exerciser mode) requires a clock to both the Clock-A-In
connector and the Clock-B-In connector on the front panel. The Clock-A-Out connector
outputs the identical signal that was supplied to the Clock-A-In connector. The
Clock-B-Out connector outputs the identical signal that was supplied to the Clock-B-In
connector. You can use Clock-A-Out and Clock-B-Out to pass through the actual DUT
onboard clock. If the Host DUT connects to port A, its Tx clock-out port should connect
to Clock-A-In. Then, the Clock-A-Out can connect to the Device DUT Rx clock-in port. On
the opposite side, the Device DUT Tx clock-out port should connect to Clock-B-In. Then
Clock-B-Out can connect to the Host DUT Rx clock-in port.
Note:
The Clock Out feature is only supported on Voyager M3i.
If Voyager is in Host Emulation mode, connect the clock to the Clock-A-In connector. The
Exerciser uses this clock as its transmit clock and provides the identical output to the
Clock-A-Out connector.
If Voyager is in Device Emulation mode, connect the clock to the Clock-B-In connector.
Example setups using Voyager USB 3.0 in Exerciser Device Emulation mode over
SMA inputs with External Slow Clock option
The Exerciser uses this clock as its transmit clock and provides the identical output to the
Clock-B-Out connector. The analyzer scales down the timestamps in trace files to the
clocks in use, so a symbol remains a 2-ns entity regardless of the clocking frequency
value. All time values displayed in trace information reflect this scaled value, allowing
easy comparison with the USB 3.0 specification. If the DUT provides its own Tx clock,
you can connect the DUT clock to Clock In.
Note 1
: LeCroy recommends using a LVPECL clock driver, which can drive a 50-ohm
load with a minimum peak-to-peak voltage swing of 200 mV. Maximum peak-to-peak
voltage swing should not exceed 1700 mV. Note that these voltages are single ended,
because only one of the differential signals is connected using the coaxial cable.
Содержание USB Protocol Suite Advisor T3
Страница 4: ...USB Protocol Suite User Manual LeCroy Corporation ...
Страница 168: ...Chapter 7 Display Options USB Protocol Suite User Manual 154 LeCroy Corporation ...
Страница 290: ...Chapter 10 Recording Options USB Protocol Suite User Manual 276 LeCroy Corporation ...
Страница 357: ...USB Protocol Suite User Manual Chapter 12 Traffic Generation 3 0 Exerciser LeCroy Corporation 343 Typical CP8 Pattern ...
Страница 358: ...Chapter 12 Traffic Generation 3 0 Exerciser USB Protocol Suite User Manual 344 LeCroy Corporation ...
Страница 368: ...Appendix A China Restriction of Hazardous Substances Table USB Protocol Suite User Manual 354 LeCroy Corporation ...
Страница 372: ...Limited Hardware Warranty USB Protocol Suite User Manual 358 LeCroy Corporation ...
Страница 388: ...Index USB Protocol Suite User Manual 374 LeCroy Corporation ...