49
8
Using a suitable fork or pliers wrench (5TB Tool 4) to the position and release the spanner
flats of the housing (5TB.400.30.60.38.0). Unscrew afterwards.
Tap the nozzle with a soft-face hammer to loosen the nozzle holder. Reposition the nozzle
holder lightly by hand. Do not yet remove the nozzle holder from the 5TB.
Unscrew all four nozzles and lay them down. Wrench size 13.
7
DISASSEMBLY SPRAY HEAD UNIT
Содержание IntenseClean Hygienic 5TB Series
Страница 1: ...Wartungsanleitung IntenseClean Hygienic Baureihe 5TB Wartungsanleitung Maintenance Instructions...
Страница 2: ......
Страница 12: ...12 DEMONTAGE SPR HKOPFEINHEIT Getriebe 5TB 400 30 20 13 0 entnehmen...
Страница 17: ...17 DEMONTAGE SPR HKOPFEINHEIT 11 1 x O Ring 60 x 1 und 1 x O Ring 52 x 1 abziehen 1 x O Ring 26 x 1 5 abziehen...
Страница 18: ...18 1 x Dichtring 35 x 30 x 4 und 1 x Lager 48 5 x 31 5 x 5 entnehmen DEMONTAGE SPR HKOPFEINHEIT...
Страница 35: ...Maintenance manual IntenseClean Hygienic Series 5TB Wartungsanleitung Maintenance Instructions...
Страница 36: ......
Страница 46: ...46 DISASSEMBLY SPRAY HEAD UNIT Remove gearbox 5TB 400 30 20 13 0...
Страница 51: ...51 DISASSEMBLY SPRAY HEAD UNIT 11 Remove O ring 60 x 1 and O Ring 52 x 1 Remove O ring 26 x 1 5...
Страница 52: ...52 Remove 1 x sealing ring 35 x 30 x 4 and 1 x bearing 48 5 x 31 5 x 5 DISASSEMBLY SPRAY HEAD UNIT...