7
IMPORTANT WARNINGS
Electrical Connection and Security
1.
Your oven requires 40 Amp fuse for mono phase or 3x16 Amp fuse
for 3 phase supply according to electrical power for cooker section has
4 ceramic heater and oven section has electric models. Installation by a
qualified electrician is mandatory.
2.
Your oven is adjusted in compliance with 220- 240V
~
50/60 Hz
electric supply. If the mains are different from this specified value, con
-
tact your authorized service.
3.
Electrical connection of the oven should only be made to connections/
sockets with an earth system installed in compliance with local regula-
tions. If there are no connections/sockets with an earth system in place
where the oven will be installed, immediately contact a qualified electri
-
cian to install. The manufacturer is not responsible for damages that will
arise because of the appliance not be connected to an earth system.
4.
If your supply cable gets damaged, it should be replaced by an
authorized service agent or qualified electrician in order to avoid danger
or electric shock.
5.
Electrical cable should not touch the hot parts of the appliance.
6.
The oven should be using a well ventilation place and should be
install on flat ground.
7.
Operate your oven in dry atmosphere.
8.
When placing your oven to its location, ensure that it is at the counter
level. Bring it to the counter level by adjusting the feet if necessary.
ELECTRICAL WIRING SCHEME
220-240V~50/60Hz
400V 3N~50/60Hz
400V 2N~50/60Hz
Earth
Terre
Erdung
Earth
Terre
Erdung
Earth
Terre
Erdung
L3
L2
L1
L2
L1
Live
Phase
Neutral
Neutre
Neutral
Neutre
Neutral
Neutre
FUSE SWITCH (25A/40A)
JUNCTION BOX
3x4mm²
3x4mm²
610mm
H05 VV-F 3G 4mm² H05 VV-F 5G 1.5mm² H05 VV-F 4G 1.5mm²
CONSUMER UNI
T