background image

36

37

Select the sensor in the app to set temperature and humidi-
ty limits by sliding the toggle button from left to right. 
     If you are worried about freezing pipes, we recommend
     setting the lower temperature to 20 F
     If you are worried about humidity causing mold, we   
     recommend setting the upper humidity limit to 40%. 
Activate alerts for movement by also sliding the toggle but-
ton left to right. 
     The movement sensor notifies you if the sensor has been 
     accidentally moved or flipped over.

Temperature & Humidity Settings & Alerts

1

2

1a

1b

2a

Tap

 Finish.

Tap Protect

 to have this sensor automatically shut off the 

water and send alerts when it detects a leak. This mode 
requires a previously installed LeakSmart shut-off valve 
Tap 

Detect-Only

 to have this sensor only send alerts 

when it detects a leak.

Select the sensor in the app to configure Protect or Detect 
settings

Protect/Detect Settings & Alerts

1

1a

1b

2

Y88501PM Protect Shutoff vlv Manual_REV 9.2021.indd   36-37

Y88501PM Protect Shutoff vlv Manual_REV 9.2021.indd   36-37

9/2/21   10:20 AM

9/2/21   10:20 AM

Содержание 8853300

Страница 1: ...ow to download the LeakSmart app setup your new system Follow the instructions in the app to setup your new sensor Use this guide for any questions Y88501PM Protect Shutoff vlv Manual_REV 9 2021 indd...

Страница 2: ...mote Control of the Valve Control Head 20 Table of Contents Table of Contents Section III Protect by LeakSmart Flow Meter Shut Off Valve Installation 22 Pre Installation Assembly 22 Installation Assem...

Страница 3: ...e installed In the Box Not Pictured 1 3 5 7 2 4 6 8 9 10 Note Additional fittings may be required based on installation requirements Encuentra nuestro manual en espa ol en LeakSmart com support manual...

Страница 4: ...oor use only For outdoor use of the valve utilize the approved enclosure box available from LeakSmart To set up the LeakSmart System you need Wi Fi An iOS or Android phone or tablet A free LeakSmart a...

Страница 5: ...are used to activate the hub It s best practice to get that information before starting the installation process 2 3 4 5 6 7 1 Activate Account Go to your email Open the email from noreply mywaterale...

Страница 6: ...Installation LeakSmart Hub 3 0 Installation 3 2 3a Slide the on off button to the ON position Central location place hub in a location central to other devices A solid red light on top of the hub indi...

Страница 7: ...tablet to the LeakSmart XXXX network Return to the LeakSmart app 1 2 3 4 5 Note If the LeakSmart Hub network does not appear perform a factory reset 7 6 Tap the name of the homeowner s Wi Fi network...

Страница 8: ...ates that the hub is ready for factory reset Turn the hub off then back on The LeakSmart hub will then show up on the Wi Fi network Tap LeakSmart XXXX to join the network Performing a Factory Reset If...

Страница 9: ...sure to replace it with a low voltage extension cord We recommend the LeakSmart low voltage extension cord Protect by LeakSmart Setup Protect by LeakSmart Setup 1 2 3 Keep the LeakSmart valve control...

Страница 10: ...the hub When the valve control head rapidly flashes blue or all the lights turn off you ve successfully paired it to the hub Verify that the valve appears in the app before moving on 1 2 3 4 5 Note Th...

Страница 11: ...pp On the home screen Tap the Open button Then tap the Close button Test Local and Remote Control of the Valve Control Head Test Local and Remote Control of the Valve Control Head Green light indicate...

Страница 12: ...t off valve and set aside Flow meter coupling assemble downstream from the shut off valve Pipe dope thread tape use on mating threads Direction of Flow 1 Protect by LeakSmart Flow Meter Shut Off Valve...

Страница 13: ...est vertically or horizontally NOT upside down Do not solder fittings near the water meter or the Protect by LeakSmart valve system to prevent heat from affecting the devices 2 4 1 3 Shut off valve fl...

Страница 14: ...he shut off valve by sliding it over the motor housing until it clicks into place Ensure that the valve control head is firmly engaged on the shut off valve 5 6 7 7 Valve control head reattach to the...

Страница 15: ...lation Assembly Installation Assembly 10 10a 10b 11 Valve control head press open to check functionality 10 10a Green light indicates open opening CAUTION Be aware of the water hammer effect when firs...

Страница 16: ...the Current Flow Rate screen Turn off the fixture and leave the valve open 1 2 3 4 5 6 7 For testing of flow meter functionality ensure the main water is on fixtures are closed and the valve is open C...

Страница 17: ...DO NOT REPLACE THE BATTERY DOOR A chirp from the sensor indicates that the batteries have been installed Open the LeakSmart app on your phone or tablet Tap Add Devices from the home screen and choose...

Страница 18: ...the pairing is successful a green light on top of the sensor will blink slowly five times and you ll hear three quick beeps The sensor will now be visible within the app on the home screen With the s...

Страница 19: ...if the sensor has been accidentally moved or flipped over Temperature Humidity Settings Alerts 1 2 1a 1b 2a Tap Finish Tap Protect to have this sensor automatically shut off the water and send alerts...

Страница 20: ...to test the response Ensure your valve is in the open position Press and hold the damp cloth to the gold pins on the back of a sensor so that the sensor begins to beep If this sensor is set to Protect...

Страница 21: ...ion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the re...

Страница 22: ...in the U S A Made in China Y88501PM 2021 LeakSmart Inc All rights reserved This product can expose you to chemicals including lead which is known to the State of California to cause cancer birth defec...

Отзывы: