SECURITY TIPS 

WARNING!!!  To  reduce  the  risk  of  fire,  electric  shock,  or 
injury to persons, follow these important safety instructions: 

 

non-professionals,  not  to  disassemble  the  light  arbitrarily  and 
lighting accessories inside.   

 

rated voltage range: AC110V-120V/60Hz or AC200V-240V / 50HZ 
(to be selected).   

 

not  beam  irradiate  the  flammable  materials,  flammable  materials 
and the lamp should be maintained at least 1M over the distance.   

 

lamps  used  in  ambient  temperature:  -15 

  -40 

,  the  highest 

temperature of the surface of the lamp: 60 

.   

 

to keep away from the liquid substance and humid environment.   

 

before  using  the  lights  must  ensure  the  good  grounding,  can  not 
install charging and remove any parts.   

 

the  installation  of  lamps,  must  be  fixed  screw  fasteners  with 
additional security cable and regular inspection.   

 

lamps  consecutive  working  hours  is  not  recommended  more  than 
10 hours.   

 

should  stop  using  the  lights  in  time  when  happens  unusual 
conditions during the process   

 

lamp  parts  of  the  rotation,  external  accessories  and  paste  parts 
should  be  regular  inspected,  such  as  the  emergence  of  loose  and 
rock,  should  be  reinforced  in  a  timely  manner  to  prevent  the 
accident.   

 

lamps adopt strong winds to refrigerate, it is easy to accumulate the 

dust,  so  you  have  to  clean  it  weekly  especially  the  cooling  air 
opening, otherwise the dust will plug leading to poor light

 

 

 

Содержание LH-D034E

Страница 1: ...200W Warm Cool white LED COB Par light User Manual This manual contains important information Please read before operating fixture ...

Страница 2: ...environment before using the lights must ensure the good grounding can not install charging and remove any parts the installation of lamps must be fixed screw fasteners with additional security cable and regular inspection lamps consecutive working hours is not recommended more than 10 hours should stop using the lights in time when happens unusual conditions during the process lamp parts of the r...

Страница 3: ...t body Die casting Aluminum With barndoor Specification Dimmer 0 100 linearly adjustable Control Mode DMX512 Master slave Sound activated Auto mode Channel 2 4 6CH LED angle 60 Setting and Addressing 4 digit LED Cooling Forced Air Convection with 1 Fan Fan Noise 12 1 20dB Fan speed 900 2 000RPM 10 Technology Thermal management system ensures long life of LED Refresh rate 4000Hz flick free for TV a...

Страница 4: ...onfirm 2 Press MENU more than 2sec The 2Digit number will flash Then press UP or DOWN can change the value quickly Then press the ENTER to save the value you want If you don t want to save the value press MENU more than 2sec is okay NO Display Function 1 A001 DMX address 001 512 2 A b2CH A b4CH A b6 CH Channel mode select 3 CC99 Jump change 01 99 4 CP99 Gradual change 01 99 5 DE99 Pulse change 01 ...

Страница 5: ... slow to fast CH5 Warm white Linear dimmer from dark to bright CH6 Cool white Linear dimmer from dark to bright b6ch CH Function Introduction CH1 Total dimmer Linear dimmer from dark to bright CH2 Warm white Linear dimmer from dark to bright CH3 Cool white Linear dimmer from dark to bright CH4 Total strobe Strobe from slow to fast CH5 Function select 0 50 DMX Channel control 51 100 Jump change 101...

Страница 6: ... 200 Pulse change 201 255 Sound CH4 Function speed Function speed from slow to fast A2ch CH Function Introduction CH1 Total dimmer Linear dimmer from dark to bright CH2 Warm white Linear dimmer from dark to bright CH3 Cool white Linear dimmer from dark to bright CH4 Total strobe Strobe from slow to fast CH Function Introduction CH1 Total dimmer Linear dimmer from dark to bright CH2 Total strobe St...

Страница 7: ...Please connect XLR XLR control wire with every light from the output of DMX XLR connection ATTENTION Please do remember to connect one circle circuit plug on the output signal of last equipment And this circle circuit plug was connected a 120ohm resistance between terminals 2 and 3 of the CANON plug connect this circle circuit plug can avoid the signal flash phenomena of signal DMX512 during the t...

Страница 8: ...posited in the DMX controller 2 If it is in DMX mode 3 If there are 2 Master in a loop 1 Correct the DMX polarity 2 Change to the DMX mode 3 Set one piece into Slave mode Par Light Set works abnormality 1 Check if the serial is correct on the Par Light display 1 Set the right serial No on the single Par Light 8 AFTER SERVICE 1 Our company offer technical consultation to customers for ever 2 If the...

Страница 9: ... can made under the provisions of the warranty show the warranty card and purchase bills copy and enjoy free maintenance service in a specific service center or the manufacturer 2 The following will be the implementation of paid service 1 Without the effective warranty card 2 There s blank alter and no point of sale name 3 Fail caused by unresistance 4 Fail caused by transportation or unloading 5 ...

Страница 10: ...9 containing data may have changed and will not notice the change any more Company retains its right to change specifications related when product is improved Thanks for your understanding ...

Отзывы: