4
5
A
B
Models
A (Inches)
B (Inches)
LWS1.0
57”
9"
LWS1.5
63”
10"
LWS2.0
61”
12"
Upflow Softener Models
Model
System Capacity Grains
Flow Rate
Regeneration Water
Usage (Gallons)
Mineral
Tank Size
Resin
Cu. Ft.
Brine Tank
Size Inches
Salt
Capacity
(Lbs)
Ship
Weight
(Lbs)
@ 10 lbs/
cu ft
@ 6 lbs/cu ft
(
Factory Setting)
@ 3 lbs/
cu ft
Service
USGPM
Backwash
USGPM
Clean Water
(Factory Setting)
Problem
Water
LWS1.0
30,000
25,000
15,000
10.0
2.0
43.4
64.3
9 x 48
1.00
18.1x34.7
270
110
LWS1.5
45,000
37,500
22,500
12.0
2.4
62.7
90.3
10 x 54 1.50
18.1x34.7
270
141
LWS2.0
60,000
50,000
30,000
15.0
3.5
87.1
124.6 12 x 52 2.00
20.3 x 37.4
385
158
SPECIFICATION
SYSTEM DIMENSIONS
Working Temperature:
This unit must be
operated at temperatures between 40°F and
110°F (4°C - 43°C).
Working Pressure:
This water softener
must be operated on pressures
between 30 psi to 125 psi. If the water
pressure is higher than 125 PSI, use a
pressure reducing valve in the water supply
line to the softener.
Voltage = 120V / 60 Hz
Pipe Size = 3/4” and 1”
• At the stated service flow rates, the
pressure drop through these devices will
not exceed 15 psig.
• The manufacturer reserves the right
to make product improvements which
may deviate from the specifications
and descriptions stated herein, without
obligation to change previously
manufactured products or to note the
change.
*Choose
HIGH EFFICIENCY
to minimize salt usage. Your system will
regenerate a little more often but your salt usage can be reduced by
20% compared to the
STANDARD
setting. Choose
STANDARD
when
you need to maximize your capacity but still operate the system with
good efficiency. Choose
HIGH CAPACITY
if you have problem water
containing Iron, Manganese or hardness in excess of 50 gpg. The high
salt setting will be needed since these minerals are more difficult to
clean out of the resin bed. Note: A resin cleaner will also need to be
periodically added to the brine tank to insure proper operation.
Peak flow rates intended for intermittent use only (10
minutes or less) and are for residential applications only.
Do not use peak flow rate for commercial applications
or for a continuous rate when treated water supplies are
geothermal heat pump, swimming pool, etc.
For satisfactory operation, the pumping rate of the well
system must equal or exceed indicated backwash flow rate.
All units come with plastic bypass
Maximum Hydrogen Sulfide
= 0.0 ppm
Maximum Manganese
= .75 ppm
pH
= 6.5 to 8.5 with no iron present with iron present
6.5 - 7.5
CAUTION!
Do not use where the water is microbiologically
unsafe or with water of unknown quality without
adequate disinfection before or after the unit.