Leadshine Technology DM870 Скачать руководство пользователя страница 4

                               

DM870 Digital Stepping Driver Manual V1.0

 

Tel: +086 0755-26434369                                3                                  Web Site: www.leadshine.com 

 

 

Operating Environment and other Specifications 

Cooling 

Natural Cooling or Forced cooling 

Environment 

Avoid dust, oil fog and corrosive gases 

Ambient Temperature 

0

 

  40

 (32

 

  104

Humidity 

40%RH 

  90%RH 

Operating Temperature 

70

 (158

) Max 

Operating Environment 

Vibration 

5.9m/s

Max 

Storage Temperature 

-20

 

  65

 (-4

 

  149

Weight 

Approx. 280g (10 oz) 

3. Pin Assignment and Description 

The DM870 has two connectors, connector P1 for control signals connections, and connector P2 for 
power  and  motor  connections.  The  following  tables  are  brief  descriptions  of  the  two  connectors. 
More detailed descriptions of the pins and related issues are presented in section 4, 5, 9. 

Important

 NOTE

 

The driver must be mounted vertically onto 

a plate or a heat sinking to maximize heat sink area as shown 

in the above picture. Please use additional heat sinking or cool 

fan if necessary. 

 

 

                               

DM870 Digital Stepping Driver Manual V1.0

 

Tel: +086 0755-26434369                                4                                  Web Site: www.leadshine.com 

Connector P1 Configurations 

Pin Function 

Details 

PUL+ 

PUL- 

Pulse signal: In single pulse (pulse/direction) mode, this input represents pulse 
signal,  each  rising  or  falling  edge  active  (software  configurable);  4-5V  when 
PUL-HIGH,  0-0.5V  when  PUL-LOW.  In  double  pulse  mode  (pulse/pulse)  , 
this input represents clockwise (CW) pulse

active both at high level and low 

level  (software  configurable).  For  reliable  response,  pulse  width  should  be 
longer  than  2.5

μ

s.  Series  connect  resistors  for  current-limiting  when  +12V  or 

+24V used. The same as DIR and ENA signals. 

DIR+ 

DIR- 

DIR  signal:  In  single-pulse  mode,  this  signal  has  low/high  voltage  levels, 
representing  two  directions  of  motor rotation; in  double-pulse  mode (software 
configurable),  this  signal  is  counter-clock  (CCW)  pulse

active  both  at  high 

level and low level (software configurable). For reliable motion response, DIR 
signal should be  ahead  of  PUL  signal by  5

μ

s  at least. 4-5V  when DIR-HIGH, 

0-0.5V  when  DIR-LOW.  Please  note  that  rotation  direction  is  also  related  to 
motor-Drive  wiring  match. Exchanging the  connection  of  two  wires  for  a  coil 
to the Drive will reverse motion direction.   

ENA+ 

ENA- 

Enable signal: This signal is used for enabling/disabling the Drive. High level 
(NPN  control signal,  PNP  and  Differential  control  signals  are  on the  contrary, 
namely  Low  level  for  enabling.)  for  enabling  the  Drive  and  low  level  for 
disabling the Drive. Usually left 

UNCONNECTED (ENABLED)

Selecting Active Pulse Edge and Control Signal Mode 

The DM870 supports PUL/DIR and CW/CCW modes and pulse actives at rising or falling edge. See 

more  information  about  these  settings  in  Section  13.  Default  setting  is  PUL/DIR  mode  and  rising 

edge active (NPN, and PNP control signal is on the contrary).   

Connector P2 Configurations 

Pin Function 

Details 

+Vdc 

Power supply, 24~72 VDC, Including voltage fluctuation and EMF voltage. 

GND 

Power Ground. 

A+, A- 

Motor Phase A   

B+, B- 

Motor Phase B   

Содержание DM870

Страница 1: ... to any products herein to improve reliability function or design Leadshine does not assume any liability arising out of the application or use of any product or circuit described herein neither does it convey any license under its patent rights of others Leadshine s general policy does not recommend the use of its products in life support or aircraft applications wherein a failure or malfunction ...

Страница 2: ...electing Supply Voltage 8 7 Selecting Microstep Resolution and Drive Output Current 9 Microstep Resolution Selection 9 Current Settings 10 Contents II Dynamic current setting 10 Standstill current setting 10 8 Wiring Notes 11 9 Typical Connection 11 10 Sequence Chart of Control Signals 12 11 Protection Functions 12 Over current Protection 12 Over voltage Protection 13 Phase Error Protection 13 Pro...

Страница 3: ...utput for smooth system performance l Microstep resolutions programmable from full step to 102 400 steps rev l Supply voltage up to 72 VDC l Output current programmable from 0 5A to 7 0A l Pulse input frequency up to 200 KHz l TTL compatible and optically isolated input l Automatic idle current reduction l Suitable for 2 phase and 4 phase motors l Support PUL DIR and CW CCW modes l Over voltage ov...

Страница 4: ...e both at high level and low level software configurable For reliable response pulse width should be longer than 2 5μs Series connect resistors for current limiting when 12V or 24V used The same as DIR and ENA signals DIR DIR DIR signal In single pulse mode this signal has low high voltage levels representing two directions of motor rotation in double pulse mode software configurable this signal i...

Страница 5: ...the specified phase current by 1 4 to determine the peak output current Figure 4 4 lead Motor Connections Connections to 6 lead Motors Like 8 lead stepping motors 6 lead motors have two configurations available for high speed or high torque operation The higher speed configuration or half coil is so described because it uses one half of the motor s inductor windings The higher torque configuration...

Страница 6: ...e noise heating and improve reliability Note MEANWELL DRP 240 24 24VDC 240Watt power supply must be selected in order to make the whole system comply with UL standards for safety Regulated or Unregulated Power Supply Both regulated and unregulated power supplies can be used to supply the Drive However unregulated power supplies are preferred due to their ability to withstand current surge If regul...

Страница 7: ...iven motor higher Drive current will make the motor to output more torque but at the same time causes more heating in the motor and Drive Therefore output current is generally set to be such that the motor will not overheat for long time operation Since parallel and serial connections of motor coils will significantly change resulting inductance and resistance it is therefore important to set Driv...

Страница 8: ...lude stepping motor stepping Drive power supply and controller pulse generator A typical connection is shown as figure 9 Figure 9 Typical connection DM870 Digital Stepping Driver Manual V1 0 Tel 086 0755 26434369 12 Web Site www leadshine com 10 Sequence Chart of Control Signals In order to avoid some fault operations and deviations PUL DIR and ENA should abide by some rules shown as following dia...

Страница 9: ...onnect the individual components that make up your system and verify that they operate independently It is important to document each step in the troubleshooting process You may need this documentation to refer back to at a later date and these details will greatly assist our Technical Support staff in determining the problem should you need assistance Many of the problems that affect motion contr...

Страница 10: ...d PC should have 1 serial port at least for communicating with the Drive Double click ProTuner_All_Setup_V1 0 exe to begin installing the ProTuner See Figure 11 Click Next to enter the License Agreement window See Figure 12 Figure 11 Begin to install the ProTuner Note ProTuner_All_Setup_V1 0 exe can be used for all Leadshine digital drives User can get it from either Leadshine CD or website Please...

Страница 11: ...ortcut Folder in Figure 15 and continue to install the ProTuner by following Figure 16 and Figure 17 An Installation Successful window will appear if the ProTuner is installed successfully See Figure 18 DM870 Digital Stepping Driver Manual V1 0 Tel 086 0755 26434369 18 Web Site www leadshine com Figure 16 Installation information summarization Figure 17 Installing the ProTuner ...

Страница 12: ...r motor wirings DM870 DM870 Digital Stepping Driver Manual V1 0 Tel 086 0755 26434369 20 Web Site www leadshine com and try again Open the tuning software ProTuner and check Drive status by clicking Err_check If it s Phase Error check the motor motor wirings and try again If it still doesn t work after you followed all of the previous steps please contact us at tech leadshine com If the RED LED is...

Страница 13: ...otors Start Restart a Step Response test to get an optimum response Kp Proportional Gain Proportional Gain determines the response of the Drive to current setting command Low Proportional Gain provides a stable system doesn t oscillate has low stiffness and large current error causing poor performances in tracking current setting command in each step like Figure 23 Too large Proportional Gain valu...

Страница 14: ...tion and Drive Output Current MicroStep Microstep Resolution The value is Drive s microstep resolution setting and can be set from 1 to 512 The user can set the microstep with ProTuner or DIP switches See more information about setting output current of the Drive in section 7 Selecting Microstep Resolution and Drive Output Current DM870 Digital Stepping Driver Manual V1 0 Tel 086 0755 26434369 24 ...

Страница 15: ...to get an optimum value 2nd ResonanceArea Parameters for 2nd resonance area Usually between 1 2rps and 2 4rps Default Amp2 and Phase2 values are zero 3rd ResonanceArea Parameters for 3rd resonance area Usually between 2 4rps and 4 8rps Default Amp3 and Phase3 values are 128 InternerPulser There is an internal pulse generator designed for Drive self testing and anti resonance tuning You can issue a...

Страница 16: ... Manual V1 0 Tel 086 0755 26434369 28 Web Site www leadshine com OverVoltage Over voltage Protection When power supply voltage exceeds 91 1 VDC protection will be activated PhaseErr Phase Error Protection Motor power lines wrong not connected will activate this protection ErrCounter Displays current error s and current error history Erase Current Err Erase Current Err button The user can clear cur...

Страница 17: ...bove limitation or exclusion may not apply to you However any implied warranty of merchantability or fitness is limited to the 12 month duration of this written warranty Shipping Failed Product If your product fail during the warranty period e mail customer service at tech leadshine com to obtain a returned material authorization number RMA before returning product for service Please include a wri...

Отзывы: