7. GENLOCK FUNCTION (REFERENCE SETTING)
34
7.1.2
Genlock Mode
1. Under REFERENCE SETTING, set GENLOCK MODE to STAY-IN-SYNC.
Reference Section 7.2, “Selecting the Genlock Mode”
2. Under REFERENCE SETTING, select LOCK FORMAT.
Select the reference signal format.
Reference Section 7.3, “Selecting the Genlock Format”
3. Apply a reference signal to GENLOCK IN on the rear panel.
The LT 4600A can use an HD tri-level sync or NTSC/PAL black burst signal for a
reference signal. Connect cables with a characteristic impedance of 75
Ω
in one of the
following ways.
Input Method 1
Apply to one input
and terminate the
other at 75
Ω.
Input Method 2
Apply to one input
and connect the
other to another
device. Terminate
the device at the end
of the chain at 75
Ω.