19
■ Check the condensation outflow tap
(fig.4).
■ Make sure that the button on the air pressure switch is
the
“OFF-0”
position 5.
After carrying out the above-mentioned controls, connect
the compressor to the electric installation and switch the button
onto the
“ON-1”
position
(fig. 5).
To switch off the compressor
push the button to
“OFF-0”
position
(fig. 5).
In CHB models the oil level is to be checked through
the transparent tap. The oil level has to correspond to the red
mark on the tap
(fig. 3.1).
To switch off the compressor always use the button on
the air pressure switch; if you switch off the compressor by
unplugging it, the pressure in the head of the compressor
would be prevented from flowing out, and this could cause
difficulties when using the compressor again.
Do not pull the cable to unplug the compressor and avoid
placing the compressor in cold environments. It is advisable
not to use extensions of any kind during normal
operation
of the compressor.
The functioning of the compressor is adjusted by the air
pressure switch
(fig. 5),
which interrupts network supply when
the pressure inside the tank reaches the set value (
15 bar
) and
reconnects the compressor to the system when the pressure
reaches a level
2 bar
inferior to the set maximum level.