9.3 LED status display on the charger
Status
Description
Action
Steady light,
orange
Battery is charging.
The charger is in the main
charging phase.
Steady light,
green
Battery is fully charged, char-
ger is in trickle charge phase.
Charger can be switched off
and the battery can be used.
Steady light,
red
Error, overheating
– Check battery connection
– Measure battery voltage
– Disconnect the unit from
the battery and allow it to
cool down.
Flashing, red
Timeout in the main charge
phase, charging interrupted.
– Check battery
– Select larger charger
– Consumer too large: Switch
off consumer during char-
ging.
9.4 Power supply unit function
CPC chargers with a charge program with a starting voltage of 0 V can also be
used without a battery to supply DC consumers up to the maximum power of
the charger. It should be noted here that the output voltage drops from the
higher main charging voltage to the lower trickle charging voltage after a
short time.
Vehicles can continue to be supplied with voltage when the battery is re-
moved in order to avoid reprogramming the customer's own settings in the
on-board computer and radio system.
9.5 Switching off the unit
To switch off the unit, proceed as follows:
1. Disconnect the mains plug from the 230 V mains.
ð
The unit is switched off.
20
LEAB Automotive GmbH
Thorshammer 6
24866 Busdorf
9 Operation
LEAB Automotive GmbH